4.
ROUTINE MAINTENANCE

Troubleshooting

Whenever the appliance does not work properly, try to solve the less serious problems using
this table
FAULT
The appliance does not turn on
The water is not discharged
The inner walls of the tank are cove-
red with limestone
The cooking compartment is stained
The gas appliance does not turn on
The pilot does not go on
The main burner does not go on
The main burner does not go on
(indirect)
Excessive bleeding of the safety
valve
The cavity is not loaded (indirect)
No hot/cold water comes out of the
pot load spout
If the problem cannot be resolved, turn the appliance off and shut all the supply valves. Then
contact authorized customer service.
THE PRESENT MANUAL IS PROPERT Y OF THE MANUFACTURER. ANY REPRODUCTION, EVEN PARTIAL, IS PROHIBITED.
All manuals and user guides at all-guides.com
POSSIBLE CAUSE
The main switch is not connected
The residual current device or
circuit breaker has tripped
The drain is clogged
The water is too hard; the softener
is finished
Water quality
Poor cleanser
Insufficient rinse
Gas valve shut
Air inside pipes
Faulty piezoelectric igniter
No Gas
The pilot does not remain on
Clogged pilot nozzle
Pilot nozzle not suitable
The valve does not emit gas to
the pilot
With the pilot on
Valve tap or damaged gas valve
No water inside the cavity
Damaged cavity pressure switch
Water level too high
Limescale inside the cavity
No water
Damaged valve
Pipes clogged with limescale
No water
Damaged water valve
Pipes clogged with limescale
- 21 -
21
INTERVENTION
Connect the main switch
Restore the residual current device
or circuit breaker
Clean the drain filter
Free the drain from residues
Connect the appliance to a water
softener
Regenerate the water softener.
Descale the cooking compartment
Filter the water (see Technical Manual)
Use the recommended detergent
Rinse again
Open the gas valve
Repeat the ignition operations
Replace the piezoelectric
Open the Gas supply valve
Check the safety thermostat
efficiency (see Technical Manual) or
the thermocouple
Clean or replace the nozzle hole
Replace the pilot nozzle
Check the ignition consent contacts /
Replace the gas valve
Check the efficiency of the operating
thermostat or pressure switch (see
Technical Manual)
Replace the valve tap (see Technical
Manual)
Replace the gas valve (see Technical
Manual)
Fill the cavity
Replace the pressure switch
With the machine not in use,
open the overflow valve and drain
the excess water
Descale the cavity (see Technical
Manual)
Open the mains tap
Replace the cavity filling valve
Remove limescale from the pipes or
replace them
Open the mains tap / Replace the cavity
filling valve / Remove the limescale from
the pipes or replace them