• To remove the safety guard panel, proceed as below:
GB
(Fig.30 on page 8)
1) Lift and completely remove the upper part of the side guard;
2) Loosen the 4 screws securing the guard in place.
3) After removing the 4 screws, take off the safety guard. (Fig.31
on page 8)
4) Use a dry brush (not supplied) to remove the dust that has
built up over time with use. (Fig.32 on page 8)
5) After having thoroughly cleaned the condenser, re-assembly
the safety guard.
k) Periodic maintenance
This machine must be periodically checked (for at least every 6
months) by a specialized technician. This periodic check serves
to ensure that all the components installed and the machine
itself are at a high level of safety.
Any worn components must be replaced by an original spare
part. It is forbidden to use this machine when even only one of
its components is faulty or worn. User are prohibited to perform
periodic maintenance.
Troubleshooting
If the appliance does not function properly, please check the
below table for the solution. If you are still unable to solve the
problem, please contact the supplier/service provider.
Problems
The machine has no
operation after plug
into the electrical
socket
Dispenser tap
leakage
Food leakage from
the back of the bowl
The auger does
not turn
16
Possible cause
Possible solution
Check again the
The power cord and
connection. And
plug do not connect
make sure all the
firmly and correctly
connections are
firmly connected.
Check again the
connection. And
The tap is not fitted
make sure all the
correctly
connections are
firmly connected.
The tap piston is not
Lubricate the tap
lubricated
piston
The tap piston is
Contact the
defective
supplier.
Check again the
The bowl is not
position and reas-
fitted correctly.
sembly the bowl.
The bowl seal ring
Lubricate the bowl
is not lubricated.
seal ring.
The bowl seal ring
Replace with a new
is defective.
bowl seal ring.
The auger is
Allow the ice to be
blocked by the ice in
melted first.
the bowl.
The work mode is
not under "Granita
mode"
The condenser is
dirty.
The machine does
not make granita
Ventilation is not
sufficient
The machine nearby
to the heat source.
The front seal (A)
fitted incorrectly.
The auger is noisy
The front seal (A) is
not lubricated
during operation
The consistency is
too thick
The bowl is dirty.
Granita has black
stains
The auger seal ring
is dirty.
The dispenser tap
Tap is blocked by
doesn't release
the ice
properly
Parameter Setting of the Machine
WARNING! It is highly not recommended to change
these settings below as the machine is already ajusted to the
optimal settings by the factory default. Change the setting only
if it is necessary.
How to set
Press and hold (22) for about 6 seconds. The "PA" is shown on
the display.
Press "+" or "-" to enter the value "15" (This is the code for
entering into the setting mode).
Then, press (22) consectively to select the parameter (display
will show consectively) that you want to change. The parame-
ters are list below:
Display
Description
Temperature of Bowl I under
F1
juice mode
Temperature of Bowl II under
F2
juice mode
F3
Protection when the tempera-
C1
ture is low
Liquid temperature during
C3
first stage
Liquid temperature during
C4
second stage
Sensor probe temperature
A1
for bowl I
Select "Granita
mode"
Clean the condens-
er regularly.
Allow sufficient
ventilation
Put the machine
away from the heat
source
Check again and
put the front seal (A)
correctly.
Lubricate the front
seal (A).
Change the
consistency.
Switch off & unplug
the machine. Clean
the bowl thoroughly.
Clean again the
seal ring.
Switch off the
machine to let the
ice melt.
Setting
Factory
range
default
1°C ~ 7°C
2°C
1°C ~ 7°C
2°C
Not applicable
-13°C ~ -3°C
-5°C
5°C ~ 10°C
10°C
3°C ~ 8°C
5°C
-5°C ~ 5°C
0°C