EN
For charger: 82DPC8A
3
2
This is a diagnostic charger. The Charger LED Light (3)
illuminates in a specified order to show the current battery
status. They are as follows:
CHARGING PROCEDURE (LED
INDICATOR)
BATTERY IS CHARGING
FULLY CHARGED
BATTERY IS TOO WARM (RE-
MOVE FOR APPROX. 30 MINUTES
TO ALLOW TO COOL)
DEFECTIVE BATTERY (REMOVE
AND REPLACE WITH A NEW BAT-
TERY)
Incorrect Defect Note:
1. Put the battery pack into the charger.
•
If the status LED blinks RED, remove the battery
pack from the charger for 1 minute.
2. Put the battery pack into the charger again.
•
If the status LED blinks GREEN, the battery pack is
good.
•
If the status LED stays blinking RED, remove the
battery pack and disconnect the charger.
1
3
4
1
BLINKING
GREEN
RED
BLINKING
English
3. Wait for 1 minute and put the battery pack into the
charger again.
•
If the status LED shows blinks GREEN, the battery
pack is good.
•
If the status LED stays blinking RED, the battery
pack is defective and it is necessary to replace the
battery pack.
6.2
EXAMINE THE CHARGER
If the battery pack does not charge correctly:
1. Examine the current of the power outlet with different
machines. Make sure that the outlet works.
2. Examine that the charger contacts are not short-circuited.
3. If the charger is not under usual room temperature, move
the charger and battery pack to a location where the
temperature is between 6° C to 40° C (42.8° F to 104°
F) .
If you attempt to charge the battery pack in a warm or hot
environment, and the charger LED light is red, remove the
battery pack and let the battery cool for approximately 30
minutes.
6.3
WALL MOUNTING THE
CHARGER
1. Get the location of the wall to attach the charger.
2. Use 2 wood screws to attach the charger on the wood
studs.
3. Drill two paralleled holes 4.5" (114.3 mm) on center.
4. Use wall anchors and screws to attach the charger to the
drywall.
GREEN
For charger: GC 400
RED
If you do not use the battery pack and charger for a long
time, please remove the battery from the charger and pull
out the AC power plug.
6
WARNING
NOTE