Tecsis P3298 Manual De Instrucciones página 23

Ocultar thumbs Ver también para P3298:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

3. Specifications
Output signals
Signal type
Current (2-wire)
Voltage (3-wire)
Power supply
The power supply depends on the selected output signal
4 ... 20 mA:
DC 10 ... 30 V
DC 0 ... 5 V:
DC 10 ... 30 V
DC 0 ... 10 V: DC 14 ... 30 V
Load in Ω
Current output (2-wire): ≤ (power supply - 10 V) / 0.02 A
Voltage output (3-wire): > maximum output signal / 1 mA
Ingress protection (per IEC 60529)
Angular connector DIN 175301-803 A: IP 65
Circular connector M12 x 1 (4-pin):
Cable outlet:
The stated ingress protection only applies when plugged in using mating connectors
that have the appropriate ingress protection.
Permissible temperature ranges
Medium:
0 ... +80 °C
Ambient: -20 ... +80 °C
Storage: -40 ... +85 °C
CE conformity
EMC directive 2014/30/EU
Pressure equipment directive 2014/68/EU
RoHS conformity
Yes
For special model numbers, please note the specifications stated on the delivery note.
Operating instructions Pressure sensor, P3298
Signal
4 ... 20 mA
DC 0 ... 5 V
DC 0 ... 10 V
IP 67
IP 67
GB
23