caprari K+ Serie Instrucciones De Servicio página 19

Electrobombas sumergibles para liquidos cargados
Ocultar thumbs Ver también para K+ Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 42
7.9 Operation with inverter/converter: the use of this electronic equipment as control and regulation unit, must be studied
very carefully in order to verify that it doesn't produce electromagnetic interferences or induced currents which can reduce the
safety standard required by the ATEX norms in reference to the zone in which the equipments are working.
In any case, the following conditions must be respected:
- it is compulsory to use the inverter Danfoss VLT FC202 (ex VLT8000) serie or more recent models with better performances;
- it is compulsory to set the inner commutation frequency of the inverter at maximum 4 kHz or at the minimum
frequency admitted by the inverter;
- it is compulsory to equip the inverter with the correct battery of filters, between inverter and the motor, for the
reduction of [dv/dt];
- it is compulsory to use the inverter only in the modulation range 35 - 60 Hz.
7.10 The standard maximum ambient temperature is 40°C. A maximum ambient temperature of 60°C can be accepted on
request and following tests by Caprari S.p.A. This temperature will be indicated on the rating plate of the electric pump.
marking: CE
II 2G Ex db h IIB T4 Gb
I M2 Ex db h I Mb
TÜV IT20 ATEX 033X
Legend:
I
II
2
G / M
Ex d
II
B
T4
Gb / Mb
BUREAU VERITAS 1370
TÜV IT20ATEX 033X
Dangerous zone
Gases, vapours or mists
Gases, vapours or mists
Gases, vapours or mists
Gases, vapours or mists
Gases, vapours or mists
Caprari S.p.A.
symbol indicating compliance with Directive 2014/34/EU (commonly referred to as ATEX);
specific symbol for the explosion-proof protection;
equipment group declaration (mining);
equipment group declaration (non-mining);
equipment category declaration; (EPL);
risk typology (G=gas);
protection scheme (d = flame-proof enclosures);
apparatus group declaration (non-mining);
joints and gaps typology (gases range);
classification according to maximum surface temperature (T4 = 135°C max);
explosive atmosphere containing gas, vapours or mists + category of equipment (EPL);
identification number of the Notified Body for verifications during the production phase;
the motor conformity at the type (Enclosure III) is realized by TÜV IT0948
Category according to 2014/34/UE Directive
Zone 0
Zone 1
Zone 2
--
--
1G
2G or 1G
3G, 2G or 1G
M1
M2 or M1
K..065F.. / K.T040F..
EPL (IEC 60079-0)
Ga
Gb, Ga
Gc, Gb, Ga
Ma
Mb, Ma
996679/ATEX A 01/2021