OPErAtiON
After reading complete instructions, confirm all controls on fireplace are in the OFF
position. Plug the fireplace into a 15AMP/120Volt outlet. If the cord does not reach,
you may use an extension cord rated for a minimum of 1875 WATTS. Once the
fireplace insert has been properly connected to a grounded electrical outlet, it is
ready to operate.
OPErAtiON BY tHE cONtrOl PANEl
The controls are located behind the 2 front covers at the top right and left corners of
the insert, and can be accessed by gently pushing the bottom of the covers.
O/I: Press this button for main power function. The unit will beep and the indicator
light will be on. Press again will stop the main power function. Once the heater is
switched off, the indicator light will flash and the unit will keep working with air flow
for 5 more seconds.
: Press this button once for flame effect. The unit will beep and the indicator
light will be ON. The bulbs for flame effect & log-set will be ON. To adjust
the flame intensity, hold down the button – the flame optics will go higher or
lower. Once you have found the desired setting, release the button. Pressing
the button again will stop the light function.
750W: Press this button for low heat level. The unit will beep, the indicator light will
be on. The fireplace heater will give low heat level. Pressing once again will stop the
low heat level function.
1500W: Press this button for high heat level. The unit will beep, the indicator light
will be on. The fireplace heater will give high heat level. Pressing once again will
stop the high heat level function.
Temperature Control: To adjust the temperature to your individual requirements,
turn the temperature control dial to the right (clockwise) to increase the desired
temperature and to the left for lower temperature. This temperature control dial
can only be used while the O/I switch and 750W & 1500W switches are in the ON
position.
Note: When the O/I switch is turned off, all other heater functions will stop even
though the switches may be in the on position.
Note: In order to shut down the heater safely, it is recommended to turn the
temperature control knob to lowest setting and allow the heater to cool down before
press the O/I switch to off position.
OPErAtiON BY tHE rEMOtE cONtrOl
Plug in your electric fireplace and it will beep once. This means
you have power and your remote is ready to operate your electric
fireplace.
0/I: Press this button for main power function. The unit will beep
and the indicator light will be on. Press again will stop the main
power function.
Once the heater is switched off, the indicator light will flash and
the unit will keep working with the air flow for 5 more seconds.
: Press this button once for flame effect. The unit will beep
and the indicator light will be ON. The bulbs for flame &
log-set will be ON. To adjust the flame intensity, hold down
the button – the flame optics will go higher or lower. Once
your have found the desired setting, release the button.
Pressing the button again will stop the light function.
750W: Press this button for low heat level. The unit will beep and indicator light will be
ON. The fireplace heater will give low heat level. Press once again will stop the low
heat level function.
1500W: Press this button for high heat level. The unit will beep and indicator light will
be ON. The fireplace heater will give high heat level. Press once again will stop the
high heat level function.
rEMOtE cONtrOl BAttErY rEPlAcEMENt
Replace with 2 AAA batteries.
wARNINg: DO NOT MIx OlD AND NEw bATTERIEs. DO NOT MIx AlkAlINE,
sTANDARD (CARbON-ZINC), OR REChARgEAblE (NICkEl CADMIuM)
bATTERIEs.
MAiNtENANcE
Disconnect power and unplug the power cord before attempting any maintenance or
cleaning to reduce the risk of fire, electric shock or damage to persons. The bulbs in
your unit can become extremely hot. Allow at least 10 minutes between turning off the
unit and removing the light bulbs to avoid the accidental burning of the skin.
RIsk Of fIRE: DO NOT ExCEED ThE RECOMMENDED bulb wATTAgE.
rEPlAciNG tHE FlAME EFFEct liGHt
AND lOG-SEt liGHt BUlBS
Step 1: Remove the 2 screws on the front of the fireplace
and open the glass window.
Step 2: Remove the screws from both sides of the log set bed.
Step 3: Remove the log set bed. You will find 2 x 40 Watt type E-12 bulbs.
Step 4: Loosen, remove and replace the burnt out bulb(s).
Step 5: Set the log set bed back into place and re-attach the screws.
Step 6: Close the glass window and re-attach the screws.
Step 7: Plug in the unit.