( NOTE: When you find error codes, first check the operation of the stove and its
components). You will see "BLOCK" on the screen. After checking and correcting the
following connection, parts and values according to the error code, the error code should
be cleared by pressing P2 for 3 seconds. When the error code clears, contact your dealer
for any remaining malfunctions.
Error
code
Er01
Er02
Er03
Er04
Er05
Er07
Er08
Er09
Er10
14
Explanation
Safety limit thermostat error
- fuel chamber overheating
(more than 90°)
Chimney
emission
switch error
Drop
in
stack
temperature or auger failure
Boiler
water
temperature
overheating
Chimney
outlet
temperature error / smoke
temperature sensor error or
cleaning error
Stack Emission Fan Motor
Error
Stack Emission Fan Motor
Encoder Error
Low pressure in the boiler
water
High pressure in boiler water
Solution
On the first screen when the stove display starts
to work, you can find ER01. Press
to clear the error code. Check sanitary valves and
pump. Push in the black prong of the safety limit
thermostat, located on the back of the boiler. (see
page 9)
Check stack connections and stack emissions.
safety
Make sure the chimney and second ashtray are
clean
Check if there is fuel in the combustion chamber
outlet
and if the fuel is supplied by the auger.
Check if the sanitary valves are open and if the
pump works. Bleed air from radiators.
over-
This error occurs when the calibration values are
increased or when the general cleaning time is
reached. Please do a general cleaning of the
product.
Check that your chimney is not clogged and
restart it. Make sure the chimney and second
ashtray are clean. If the error persists, contact
your dealer.
Reset the alarm and if the error persists, contact
your dealer.
Check the manometer and in case of low pressure
supply water to the hydraulic circuit.
Check the pressure gauge and make sure the
water pressure is in the range of 1-1.5 bar. If the
pressure
is
high,
reduce
the
the button
pressure
by