9) DIAGNOSTICS

SWO1
SWO2
SWC1
SWC2
P.P.
PED
OPEN
PHOT
STOP
PHOT-C
DAS

10) ERROR MESSAGES

Some messages that are displayed in case of function anomalies are listed as follows:
Obstacle error motor 1/anti-crushing
Amp1
Amp2
Obstacle error motor 2/anti-crushing
Error, encoder 1/detection of the obstacle
ENC1
Error, encoder 2/detection of the obstacle
ENC2
Err1
Motor 1 circuit checking error
Motor 2 circuit checking error
Err2
error/fault power circuit
Err3
Err4
PHOTA photocell checking error
Err5
PHOTC photocell checking error
Error edge active (during autoset)
Err6
Error active stop (during autoset)
Err7
Err8
Error active input (during autoset)
Motor 1 thermal protection intervention
thm1
Motor 2 thermal protection intervention
thm2
COM1
Motor 1 communication error
Motor 2 communication error
COM2
BAR
Activating BAR input
One segment of the display is linked to each input. In the event of failure it switches on according
to the following scheme.
CLOSE
N.C. inputs are represented by the vertical segments. N.O. inputs are represented by the horizontal
segments.
The control unit sees the message AMP1 or AMP2 in case of anti-crushing ammeter sensor inter-
vention.
Check presence of obstacles on motor 1 leaf run
Check presence of obstacles on motor 2 leaf run
Check the correct connection of motor 1 encoder to the control unit, that no obstacles
are present along the gate stoke and the encoder operates correctly.
Check the correct connection of motor 2 encoder to the control unit, that no obstacles
are present along the gate stoke and the encoder operates correctly.
Check motor 1 connections
Check motor 2 connections
Request technical assistance and eventually replace control unit.
Check connections, PHOT A photocell alignment or presence of obstacles.
Check connections, PHOTC photocell alignment or presence of obstacles.
In autoset phase, the safety edge has intervened.
In autoset phase, the STOP input has intervened.
In autoset phase a PP/Open/Close input has intervened.
Wait for motor M1 cooling, in case reset does not take place, motor replacement may
be necessary
Wait for motor M2 cooling, in case reset does not take place, motor replacement may
be necessary
Only for HD.3524 and HD.5024 motors: Communication error between motor Encoder
and central unit, check Motor 1 Encoder connections
Only for HD.3524 and HD.5024 motors: Communication error between motor Encoder
and central unit, check Motor 2 Encoder connections
BAR input has detected an obstacle.