Parameters table
Description
0
Automatic restart
1
START/STOP times programming
2*
Adjustment of temperature difference for restart
3**
Adjustment of compressor shutdown margin
4
Auto-activation time before de-icing commences
5
De-icing activation temperature
6
De-icing deactivation temperature
7
Maximum de-icing duration
8
Compressor thermal protection
9
Maximum temperature
10
Filtration pump servo-control mode
Pump stopping time when temperature reached
11
(if setting 10 = 1)
12
Reserved - Do not modify
13
Reserved - Do not modify
14
Water intake temperature
15
Water outlet temperature
16
Coil temperature
17
Air outlet temperature
18
Ambient air temperature
* Setting 2 is for modifying the interval of degrees lost in relation to the required temperature, for the heat pump to restart.
Example: If the value of setting 2 is 3°C, after reaching the required temperature
(e.g. e.g. 27°C), the heat pump will restart when the pool temperature goes down to 24°C (27 - 3).
** Setting 3 is for modifying the degree of accuracy for heat pump shutdown.
Example: By configuring the compressor shutdown at 2°C and the required temperature at 27°C, the heat pump will cease working
when it reaches a pool temperature of 29°C (27+2).
4. Use
Adjustment range
0 = Off
1 = On
0 = start only
1 = daily
Adjustable from 2 to 10°C
Adjustable from 0 to 3°C
Adjustable from 30 to 90 mins
Adjustable from 0 to -30°C
Adjustable from 2 to 30°C
Adjustable from 0 to 15 mins
Adjustable from 95 to 120°C
Displayed values
95 → 96 → 97 → 98 → 99 → A0 → A1 →
A2 → A3 → A4 → A5 → A6 → A7 → A8 →
A9 → b0 → b1 → b2 → b3 → b4 → b5 →
b6 → b7 → b8 → b9 → C0
40~65°C
0 = Normal
1 = Special
Adjustable from 3 to 20 mins
0 / 1
0 / 1 / 2
-9~99°C
-9~99°C
-9~99°C
-9~99°C
-9~99°C
25
Factory
Remarks
setting
1
Adjustable
1
Adjustable
3°C
Adjustable
0°C
Adjustable
40 mins
Adjustable
0°C
Adjustable
2°C
Adjustable
10 mins
Adjustable
118°C
Adjustable
Displayed
b8
value
40°C
Adjustable
Adjustable
1
(see Section 5.2)
15 mins
Adjustable
1
Adjustable
2
Adjustable
Actual data
Actual data
Actual data
Actual data
Actual data