POSSIBLE MALFUNCTIONS
FAILURE
Filter housings
Connectors (threaded part)
Connectors (tube part)
WATER LEAKS
Faucet
The tank is full
LOW PRODUCTION
When open the faucet,
the supply stops
immediatly, remaining
a slight continuous flow.
The tank is empty
Tank does not fill
LOW PRODUCTION
The equipment rejects
water continuosly into
the drain
Tank is full enough
THE EQUIPMENT
The tank is empty
IS NOT PRODUCING
CHANGE ON THE
WATER TASTE
Water has a milky appearance
POOR APPEARANCE
after flowing from the faucet
WATER
ORIGIN
06
SOLUTION
O-ring dirty, misplaced or pinched
Needs teflon
Bicone wrong installed
Connector not threaded enough
Pinched or wrong cutted tube
Adjunt the handle height
if worn, replace faucet
Lack air in the tank. Replenish between 0.3 and 0.5 kg
The tank valve is closed
Chopped accumulator membrane,
water flows through the air inlet valve.
Cambiar el acumulador.
Taked between 3 and 5 hours to have the tank full.
The water tank inlet is closed
Too much air in the tank. Check the pressure between
0.3 Kg. and 0.5 Kg.
Dirty filters. Change
The inlet pressure is less than 3kg/cm². Install a pump
Change the membrane
Flushing valve opened
The check elbow placed in the membrane housing does
not work. Change
Shutoff valve is dirty or the membrane is not working.
Change
Pressure is not enough.
Install a water pump.
Possible water leak
Blocked filters
Blocked, broken or closed inlet valve
Blocked membrane
Change on the water mineralization due to saturation
or to filters or membrane blockage (change them)
Flow restrictor or drain blocked. Check
Shutoff valve in poor condition. Change
Membrane housing in poor condition. Change
Air bags accumulated in the pipes
or in the R.O. equipment