Osmofilter Blue Ocean Manual De Instrucciones página 20

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

POSSIBLE MALFUNCTIONS
FAILURE
Pump does not stops
EQUIPMENT
WITH PUMP
Pump does not starts
Equipment does not produce water
ORIGIN
07
SOLUTION
High pressure switch is missplaced. Check
High pressure switch broken. Change
Flushing opened
Possible water leak
The tank is not full enough
(wait between 2 and 4 hours)
The inlet valve is closed, broken or blocked.
Low pressure switch is defective. Check
Low pressure switch is brocken. Change
The transformer is defective. Check
Pre-filtration filters are blocked
The pump does not start

Publicidad

Tabla de contenido
loading

Tabla de contenido