Declaration in accordance with Directives 2004/108/CE (EMC); 2006/95/CE (LVD)
The Manufacturer:Automatismi CAB Srl
Address:Via della Tecnica, 10 (z.i.) - 36010 Velo d'Astico (VI) - Italy
Declares that the product:
Control box for 1 or 2 230V AC motors, model:
CIDRA RI-C
conforms with the requirements of the following EU Directives:
• DIRECTIVE 2004/108/CE OF THE EUROPEAN PARLIAMENT AND COUNCIL, 15 December 2004, in relation to the
harmonisation of the legislation of member states regarding electromagnetic compatibility , in abrogation of Directive 89/336/CEE,
per the following harmonised standards:
EN 61000-6-2:2005, EN 61000-6-3:2007
• DIRECTIVE 2006/95/CE OF THE EUROPEAN PARLIAMENT AND COUNCIL, 12 December 2006, in relation to the
harmonisation of the legislation of member states regarding electrical material intended to be used within certain voltage ranges, per
the following harmonised standards:
EN 60335-1:2002 + A1:2004 + A11:2004 + A12:2006 + A2:2006 + A13:2008; EN 60335-1-103:2003
as applicable:
• DIRECTIVE 1999/5/CE OF THE EUROPEAN PARLIAMENT AND COUNCIL, 9 March 1999 in
relation to radio equipment and telecommunications terminals and the mutual recognition of their
conformity, per the following harmonised standards:
ETSI EN 301 489-3 V1.4.1 (2002) + ETSI EN 301 489-1 V1.4.1 (2002) + ETSI EN 300 220-3 V1.1.1
(2000) + EN 60950-1 (2001)
Benincà Luigi, Legal representative.
Velo d'Astico, 02/11/2010
The CIDRA control unit can be used to control 1 or 2 motor, with power not exceeding 500W+500W.
a) The wire connections and the operating logic should be in compliance with regulations in force.
b) The cables featuring different voltage should be physically separated, or adequately insulated by an additional insulation
of at least 1 mm.
c) The cables should be further fastened in proximity to the terminals.
d) Check all connections before powering the unit.
e) Check that setting of the Dip-Switches are the required ones.
f)
Normally Closed inputs which are not in use should be short-circuited.
The CIDRA control unit is not provided with electronic regulation of the motor torque.
Therefore, it should be used only with actuators complete with torque regulation by means of mechanical clutch
or similar devices.
Terminal No.
Function
L-N
Power supply
3-4-5
Motor 1
6-7-8
Motor 2
N-9
LAMP
10
COM
11
Step-by-Step
CE Declaration of Conformity
CIDRA Control Unit
GENERAL WARNINGS
CAUTION
INPUT/OUTPUT FUNCTIONS
Description
Input, 230VAC 50Hz (L-Phase/N-Neutral)
Connection to motor 1 : (3-move/4-Com/5-move) - delay in closing phase. Should
one single motor be used, connect Motor 1 output and adjust TRAC to the minimum
value.
Connection to motor 2 : (6-marcia/7-Com/8-marcia) - delayed in the opening
phase.
Output, connection of Flashing light 230 Vac 40W max.
Common, for all control inputs.
Input, step-by-step push button (N.O. contact)
7