About This Documentation; Documentation Validity; Additional Documentation; Abbreviations Used - Emerson AVENTICS Sentronic PLUS 614 Instrucciones De Montaje

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

1 About this documentation

Read this documentation completely, especially
ing with the product.
These instructions contain important information on the safe and appropriate as-
sembly, operation, and maintenance of the product and how to remedy simple
malfunctions yourself.

1.1 Documentation validity

This documentation applies to proportional pressure regulators from the Sen-
tronic PLUS 614 series.
This documentation is intended for:
System owners, system planning engineers, machine manufacturers, installers

1.2 Additional documentation

Observe the following related documents:
• Manufacturer's system documentation

1.3 Abbreviations used

This documentation uses the following abbreviations:
Abbreviation
Meaning
ATEX
Atmosphère explosible (EU directive on explosion protection)
AWG
American Wire Gauge (measure for wire diameters)
EPDM
Ethylene propylene diene rubber
ESD
Electrostatic Discharge
FE
Functional earth
Gas-ex
Gas explosion protection
K
Flow coefficient
V
MAP
Maximum Allowable Pressure (max. input pressure)
Nl
Normal liter of air
PELV
Protective Extra Low Voltage
PG
Panzergewinde (steel conduit thread)
PPE
Personal protective equipment
Dust-ex
Dust explosion protection

2 Safety

2.1 About this chapter

• Read this chapter and this documentation completely before working with
the product.
• Keep this documentation in a location where it is accessible to all users at all
times.

2.2 Intended use

Applications
The product was manufactured for the following applications:
• Controlling pneumatic pressures
• The product is intended for solely for professional use.
• The product is exclusively intended to be installed in an end product (a sys-
tem/machine) or to be assembled with other components to form an end
product.
Application area and location
The product is designed only for use in the following areas:
• Industrial applications
• ATEX product version only: Explosive atmospheres. See
areas.
• Indoor areas
INFO: If the product is to be used in a different area: Obtain an individual li-
cense from the manufacturer.
Notes
• The product is not a safety component in terms of the Machinery Directive.
AVENTICS™ Sentronic PLUS 614 | IM14229-R06 | English
chapter g 2. Safety
before work-
g 5.3 Use in explosive

2.3 Obligations of the operator

• The owner must ensure that persons who assemble, operate, disassemble, or
maintain products must not consume any alcohol, drugs, or pharmaceuticals
that may affect their ability to respond.
• The owner must ensure that PPE is used. Observe all specifications for the
overall system.

2.4 Personnel qualifications

Only personnel qualified for the tasks at hand are allowed to perform the activi-
ties described in this documentation. Depending on the activity, this requires ba-
sic knowledge in the following areas and knowledge of the relevant technical
concepts:
• Mechanics
• Pneumatics
• Electrics
The following specific qualifications are additionally required:
• Knowledge of the use and maintenance of ATEX products

2.5 Hazards

2.5.1 Danger of explosion due to formation of sparks

Formation of sparks due to mechanical loads
Mechanical loads lead to the formation of sparks and present an explosion haz-
ard.
• Never twist or bend the product and add-on parts, or mount them when they
are under tension.
Formation of sparks due to electrostatic discharging
Pulling out plugs when they are live leads to high differences in potential.
• Never pull out the plug when it is live (explosion protection).

2.5.2 Danger of injury

Danger of injury due to wear or malfunctions of pneumatic systems
Wear or malfunctions can cause components in pneumatic systems to fail and
trigger undesired operating states.
• Take precautions to prevent pressure loss in case of an interruption of the sup-
ply voltage. Suitable precautions are e.g. safety switching valves and/or a re-
dundant supply voltage.

2.5.3 Material damage

Damage due to too high mechanical loads
• Never twist or bend the product and add-on parts, or mount them when they
are under tension.
• Do not use the product as a handle or step.
• Do not position any objects on the product.
Damage caused by electrostatic discharge
Contact between people or objects and electrical product components can cause
electrostatic discharge (ESD), which then damages or destroys the product. Take
the following measures to prevent electrostatic discharge:
• Observe handling instructions and recommendations in accordance with EN
61340-5-1 and 5-2 (material protection).
Damage due to insufficient supply pressure
Setting the set point without applying sufficient pressure to the product will
cause the product to heat up to an impermissibly high temperature and damage
seals.
• Make sure that sufficient pressure is applied to the product before setting the
set point.
• The supply pressure must always be higher than the intended output pres-
sure.