Cleaning Of The Spray Gun - SATA minijet 1000 K RP Instrucciones De Servicio

Ocultar thumbs Ver también para minijet 1000 K RP:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 125
Operating Instructions SATAminijet 1000 K RP, SATAminijet 1000 H RP
All manuals and user guides at all-guides.com
quired material supply pressure, e.g. at the pressure tank.
7.3. Adjustment of the Spray Fan Pattern
• Adjust flat fan (factory setting) [5-1].
• Adjust round fan [5-2].
7.4. Painting
Fully pull trigger for painting [6-1]. Operate spray gun according to [6-2].
Maintain spray distance as described in chapter 2.

8. Cleaning of the Spray Gun

• Prior to cleaning, please disconnect the spray gun from the com-
pressed air circuit!
• Risk of injury due to unexpected leakage of compressed air or mate-
rial!
• Empty spray gun and suction cup completely, dispose of paint mate-
rial appropriately!
• Disassemble and install components very carefully! Exclusively use
included special tools!
• Use neutral cleaning solution (pH value 6 to 8)!*
• Do not use acids, lyes, pickling agents, unsuitable re-
claimed materials or other aggresive cleaning media, such
as Toluol, for example!*
• Do not soak spray gun in cleaning solution!*
• Drillings should be cleaned with SATA cleaning brushes or SATA nozzle
cleaning needles only. The use of other tools may cause damage or
may affect the spray pattern. Recommended accessory: cleaning kit
Art. No. 64030.
• Exclusively use spray gun washing machines recommended by SATA!
Please observe the operating instructions!
• The air passages have to be pressurized with clean compressed air dur-
ing the entire cleaning process!
• Nozzle head has to point downwards!
• Remove the spray gun from the gun washing machine imme-
diately after the cleaning process!*
Danger! Notice!
US
421

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Minijet 1000 h rp

Tabla de contenido