Connecting The Water Supply - Dometic CT 4050 Instrucciones De Montaje

Ocultar thumbs Ver también para CT 4050:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 59
CT(E), CTLP, CT(E)S, CTW
Setting up cassette toilets CTLP4xxx, CT(E)S4xxx, CTW4xxx
Set up all models with wall connection console directly against the room wall
(fig. g, page 13). A previously attached wall bracket is used to secure the cassette
toilet and the wall bracket.
1. Screw on the wall bracket, level, at the following height (fig. h, page 13):
– CTLP4050, CTLP4110: h = 479.5 mm
– CTS 4050, CT(E)S 4110: h = 651.5 mm
– CTW4050, CTW4110: h = 651.5 mm
2. Put the entire toilet module into the desired position in front of the wall bracket.
3. Lift the cassette toilet and hook the housing into the wall bracket (fig. g,
page 13).
4. Tightly fasten the base plate with six bolts (fig. a, page 10).
5. Slide in the mobile tank cassette (fig. f, page 12).
6.6

Connecting the water supply

A
NOTICE!
• CT4xxx, CTLP4xxx, CTS4xxx, CTW4xxx only: The water sup-
ply is connected using a solenoid valve mounted in the toilet housing
(fig. i 1, page 14).
• The operating pressure (water pressure) of the solenoid valve should
not exceed 6 bar.
• The solenoid valve is damaged by excessive pressure.
I
NOTE
For the CTW4xxx models with an integrated water tank, the water
connection is installed at the factory.
1. Use a spring band hose clamp to attach the freshwater supply hose to the
connection socket (fig. i 2, page 14).
2. Perform a leak test.