Before Using
Before Using for the First Time
1. Remove the exterior and interior packing materials.
2. Before connecting the refrigerator to the power source, let it stand upright for
approximately 4 hours. This will reduce the possibility of a malfunction in the
cooling system from improper handling during transportation.
3. Clean the interior surface with lukewarm water using a soft cloth.
Usage Note
1. This refrigerator operates on 12VDC, while the actual working voltage is from 10.5-
17V.
NOTE: The compressor will stop running when the voltage is lower than 10.5V.
2. This refrigerator requires 10.5-17VDC, >=15A power source for normal operating.
Direct connection with AC power source is forbidden. Otherwise, it will void any
product warranty.
3. The wire of the refrigerator and outer wire must follow RVIA and NEC standards.
4. A proper location and reliable grounding device is recommended to avoid electric
shock when using a converter to change the power source from AC to DC.
5. A qualified professional is required for any servicing of the compressor drive board
and the control board, otherwise any product warranty will be voided.