Planika Arcticon Manual De Montaje página 14

Tabla de contenido

Publicidad

TROUBLESHOOTING
Some alarms are accompanied by a sound signal. Press START/STOP to mute.
Lp.
DIODES
1.
2.
3.
4.
5.
6.
7.
-
FUEL
Use only ethanol fuel produced from plants in the process of two-time alcohol distillation consisting of 95-
96.6% ethanol by volume. Fanola is the recommended fuel with pharmacological purity.
DO NOT USE SYNTHETIC PETROLEUM BASED FUELS AS THEY ARE CONTAMINATED, EMIT UNPLEASANT
ODORS AND CAN DAMAGE THE FIREPLACE! DO NOT USE FUELS CONTAINING 100% ETHANOL BY VOLUME,
GEL, OR AROMATIC FUELS!
CLEANING
Clean with a damp cloth and delicate detergents, only when the device is turned off and cooled.
SERVICE – Keep the provided USB cable for service. Reach out to us at service@planikafires.com.
1. Ist der Brennstofftank leer (
2. Ersetzen Sie den leeren Behälter durch einen neuen (
3. Schrauben Sie den Verschluss an dem neuen Tankbehälter zu (III).
Die grüne Diode
bedeutet, dass der Kamin betriebsbereit ist.
Drücken Sie START für 3 Sekunden. Die Flammenzündung dauert 2-10 Minuten (
von Kraftstoffdämpfen zu spüren sein. Die ausgeschaltete Diode READY (
wurde und der Kamin die Betriebstemperatur erreicht hat.
(contact the Service Department if the solution does not eliminate the error)
The device is being cooled. Wait for the green diode
The device run out of fuel while operating. The device is being cooled.
Wait for the red diode to turn off. Refill the tank.
An internal fuel spill occurred. Disconnect the pump. Wipe the visible liquid and wait
for min. 1 hour. Press and hold ECO on the control panel for 10 seconds. If the error is
not eliminated, wait for min. 24 hours.
If the error occurred during flame ignition, it means that the ignition time
has been exceeded. Press and hold ECO on the control panel for 10 seconds.
Device error. Press and hold ECO on the control panel for 10 seconds.
Tank overfilled. Contact the Service Department.
Room temperature too low (<10°C) or device error. Increase the room temperature.
Press and hold ECO on the control panel for 10 seconds. Wait for the green diode
Device overheat. Please contact service department.
BRENNSTOFFNACHFÜLLEN
), nehmen Sie den Behälter aus dem Schrank heraus (
I
FLAMMENZÜNDUNG
SOLUTION
) (II).
II
bedeutet, dass die Flamme gezündet
)
14
.
) (I).
III
). In dieser Zeit kann der Geruch
.