OPERATION

Ducted Systems

Normal Ducted Use
To distribute air through a ducted system, close the air shutter
by pushing the tab right to pressurize the duct work.
Max Cool
To remove significant heat, open the air shutter to "dump" cool
air directly below the AC. This will eliminate air and heat loss in
the ducted system, and maximize cooling performance. Once

CLEANING AND MAINTENANCE

A blocked filter will impair the cooling and heating performance
of the unit significantly.
The filter must be cleaned periodically to ensure that it does
not become clogged with dust and other particles. The state of
the filter can be ascertained from its appearance. If it appears
dirty or clogged then it should be cleaned.
WARNING
Airborne particles can pose a health risk, particularly to
young children and the elderly. Ensure that filters are cleaned
in a safe and well ventilated area.
To Clean the Filter
The filter should be cleaned every four weeks or more when in
use. Prolonged use, higher concentrations of airborne particles
and various other factors may result in the filters needing to be
cleaned more often.
1.
Remove the filters by pushing the tabs to release.
CCD-0007273 Rev: 11-04-22
comfortable, close shutter to distribute evenly with the ducted
system. Open and close the shutter by pushing the tab left and
right.

Non-Ducted System

Open shutter to release air.

Thermostat Use

Based on the wall thermostat version you selected. Please
refer to the separate instruction manual on how to operate your
RV air conditioning system.
2. The filter can be washed with warm soapy water. Care
must be taken to avoid ripping the fabric.
3. Replace the filters and decoration plate, by reversing the
above process.
NOTE: The filter must be completely dry before re-
installation.
To Replace the Filter
Filter changes should be carried out depending on the amount
of use, it is recommended to change at least every 12 months.
Never operate the air conditioning system without a filter, since
this can decrease performance and indoor air quality.
Replacement return air filters can be ordered directly from
Furrion.
- 11 -