► The unit may only be plugged into electrical sockets that are connected to the protective conduc-
tor system.
► The power plug must be easily accessible.
en
► Disconnect the unit from the mains power supply before carrying out work on the electrical parts.
► It is the responsibility of the operator to ensure that national regulations are complied with during
operation and regarding recurring safety inspection of electrical equipment. In Germany, these are
DGUV Regulation 3 in conjunction with VDE 0701-0702.
► Check connection cables (such as power cords), tubes and housing (such as the key pad) regu-
larly for damage (such as kinks, cracks and porosity) or signs of ageing.
Do not operate equipment with damaged connection cables, tubes or housing parts or other de-
fects!
► Defective equipment must be taken out of service immediately. Disconnect the power plug and
secure the equipment against further use. Send the equipment in for repair!
► Only operate the equipment under supervision.
► Please observe the national accident prevention regulations!
► Information on REACH and SVHC is available on our website at www.renfert.com, in the Support
area.
Specific information
► Only the adapter provided on delivery may be used for adaption to the local power supply.
Authorized persons
Operation and maintenance of the equipment may only be performed by trained personnel.
Any repairs not described in this user information may only be performed by a qualified electrician.
Product description
General description
The SILENT flow sensor measures the flow rate that flows through it. The measured flow rate is com-
pared electronically with a threshold value defined in the unit. If the flow rate is less than the defined
threshold value for a certain period, this is indicated by an acoustic as well as a visual signal.
The SILENT flow sensor meets the requirements of Annex A, Paragraph 3 of the testing principles
GS-IFA-M20-2012-12 issued by the IFA (German Institute for Work and Health).
Assemblies and functional elements
See Fig. 1 (on inside cover)
1
Inlet nozzle (IN)
2
Indicators and operation
3
Output nozzle (OUT)
4
End bushing
5
Indicator for threshold value 15 l/s (yellow)
Scope of delivery
1 SILENT flow sensor
2 End bushings
1 Universal power plug set (only for item number 2914 1000)
4 Cable ties
1 Operating instructions
6
Indicator for threshold value 20 l/s (yellow)
7
Indicator for threshold value 25 l/s (yellow)
8
Button
9
Operating indicator (green)
- 2 -