11. Trouble shooting
Malfunction
Power indicator (red LED) (1)
remains inactive
VITO is very noisy during operation
Power indicator (red LED) (1)
flashes and acoustic signal sounds
Power indicator (red LED) (1) and filter
indicator (green LED) (2) flash and an
acoustic signal sounds
VITO doesn't start
Line fuse / Ground fault circuit fuse
(GFCI) blow-out
Low filtration performance
Oil splashed sideways and / or at the
back of the pump-filter unit (11)
Power and filter indicator (1 & 2) flash
10 sec. after plugging VITO in and an
acoustic signal sounds
Internet connection cannot be estab-
lished
"10.10.10.10"-website is not
displayed correctly
Gap between control unit (8) und
pump-filter unit (11)
If you find any faults not listed here, please contact the VITO customer service or your dealer!
Contact details can be found in chapter 2. Legal information.
12. Waste disposal
12.1 Packaging disposal
The packaging should be recycled
or
keep the packaging carefully.
12.2 Particle filter disposal
Used particle filter must be disposed according to your local regulations.
Possible cause
Power cord (10) not plugged in
Power cord (10) defective
Device defective
Star handles (7) are loose
Rotor defective
Rotor scratches on the fryer
Overtemperature
VITO is at an angle of more than 17°
Strong vibrations
Control unit (8) defective
Power cord (10) or other electrical
components defective
Rotor defective / blocked
Circuit overloaded
Particle filter is full
Pump-filter unit (11) clogged
Filter paper not inserted properly
Motor defective
Particle filter full
Too much space between filter
cover and pump-filter unit (11)
Filter paper not inserted overlapping
Start / Stop button (5) defective
Control unit (8) wet inside
Wrong network chosen
Wrong password entered
WiFi signal too weak
Outdated website in cache
Device is not connected to VITO
Filter cover not closed properly
Filter cover or pump-filter unit bent
Remedial action
Plug in VITO
Please contact service
Please contact service
Tighten star handles (7)
Please contact service
Change position of VITO in deep fryer
Let VITO cool down
Place VITO in a cool place
Check position of VITO in the fryer
Please contact service
Damaged rotating parts
Filter cover not closed properly
Please contact service
Please contact service
Please contact service
Change socket/circuit
Change particle filter
Empty pump-filter unit (11)
Boil out to remove heavy dirt
Insert filter as described
Please contact service
Change particle filter
Please contact service
Insert particle filter as described
Please contact service
Please let it dry
Select correct network
Enter correct password
Strengthen the WiFi signal
Move router closer to VITO
Delete Cache
Delete browser data
Connect to VITO (see chapter 6.5)
Close the filter cover properly and snap
it into the pump-filter unit
Please contact service