ProMinent Flow Monitor Instrucciones De Servicio página 21

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Viscosity, max. (for dynamic operation):
In the case of higher viscosity either :
• lower stroke rate or
• operate with static flow monitoring (see "Settings" - "b) static"; only in the
b) static
(gamma/ L series with Identcode characteristic "flow monitor" only: 1; only
possible from viscosity stated in "Stroke length" tab.)
ProMinent
®
Flow Control
in the case of pump types
gamma/ L
Size I
1000, 1601
1602
Size II
all
case of gamma/ L with Identcode characteristic "flow monitor": 1 (if nec.
have reprogrammed).
IMPORTANT
The indicator "Flow" will disappear when the reed-contact is
closed (the float is at the topmost position).
Unplug the flow monitor cable (to temporarily disable the flow monitor)
turn the control knob left as far as it will go (" - ")
set the required operating pressure at the discharge line
set the required feed rate at the pump while it is running (via frequency
and stroke)
plug the flow monitor cable back in
the indicator "Flow" in the pump LCD display will disappear at each
pressure surge
turn the flow monitor's control knob slowly to the right ("+"), until the
indicator "Flow" stops flashing
turn the control knob backwards slightly until the indicator "Flow" starts
flashing again
now lower the stroke length at the pump by approx. 20 % (scale division)
(note old value) - the indicator "Flow" should stop flashing. If not, turn the
flow monitor control knob slowly to the right ("+"), until the indicator
"Flow" stops flashing
set the stroke length back to the old value - the indicator "Flow" must
start flashing again.
Commissioning
Viscosity,
max. (at 180 strokes/min)
50 mPa s
100 mPa s
150 mPa s
21

Publicidad

Tabla de contenido
loading

Tabla de contenido