12 After Finishing Work
► Hold and guide the blower firmly with your
right hand on the control handle so that your
thumb wraps around the control handle.
11.2
Setting the Power Level
Depending on the application, you can set 3
power levels. The LEDs indicate the selected
power level. The higher the power lever, the
higher the volume of air that flows from the noz‐
zle.
The selected power level affects the battery's
runtime. The lower the power level, the longer
the runtime.
2
► Press and hold the trigger lockout (1).
► Push release slide (2) in direction of arrow
with your thumb and allow it to spring back.
The LEDs illuminate to indicate the selected
power level.
► Push the release slide (2) forward and allow it
to spring back.
This selects the next power level. After the
third performance level, it starts again with the
first performance level.
► Push the release slide (2) forward and allow it
to spring back as many times as necessary
until the desired power level is set.
11.3
Activating and Deactivating the
Power Lock
The power lock can be activated independently
of the selected power level. Any desired blowing
force can be locked by using the power lock but‐
ton.
2
1
► Turn on blower.
0458-724-9801-A
1
► Set the power level.
► Use trigger (1) to adjust blowing force.
► Press the power lock button (2).
The blowing force is locked. You can let go of
the trigger.
To deactivate the power lock, depress the power
lock button (2) again.
11.4
Activating the Boost Function
The boost function can be activated independ‐
ently of the selected power level. The blower
operates at maximum power when the boost
function is activated.
The boost function affects the battery's runtime.
The longer the boost function is activated, the
shorter the battery runtime.
1
► Override the trigger (1) and keep it pressed.
The LEDs flash one after the other. The boost
function is activated.
The boost function is deactivated when you
release the trigger (1). The previously selected
power level is reset.
11.5
Blowing
► Point the nozzle at the ground.
► Move forward slowly in a controlled manner.
12 After Finishing Work
12.1
After Finishing Work
► Turn off the blower and remove the battery.
► If the blower is wet: Allow the blower to dry.
► Clean the blower.
English
25