Question /Problem - Cause
The vacuum cleaner will not turn on:
� Non-existent supply voltage;
� Defective switch;
� Electric motor with fault;
Reduction of suction power:
� The supply voltage is too low;
� Hose, tubing, and suction fittings are clogged
or clogged;
� Damaged hose, tubing or fittings;
� The filters are dirty or damaged;
Solution
� Check the power cord, plug, outlet and protective circuit
breaker;
� Contact technical support;
� Contact technical support;
� Use a power supply compatible with the technical
specifications of the vacuum cleaner;
� Remove existing obstructions and clogs;
� Repair or replace damaged parts;
� Clean filters, replace if necessary;