Descargar Imprimir esta página

WIKA RLT-1000 Manual De Instrucciones página 19

Ocultar thumbs Ver también para RLT-1000:

Publicidad

Idiomas disponibles

Idiomas disponibles

9. Specifications
Model RLT-2000
Specifications
Output signal
Accuracy, resolution
Operating conditions
Medium temperature
limit
Ambient temperature
limit
Storage temperature
limit
WIKA operating instructions models RLT
Variable resistance
The overall resistance of the reed chain is approx.
1 ... 10 kΩ, depending on the measuring range
Max. voltage < DC 40 V
Current output, 2-wire
Auxiliary power: DC 12 ... 32 V
Load in Ω: ≤ (auxiliary power - 12 V) / 0.02 A
Voltage output, 3-wire
Auxiliary power: DC 12 ... 32 V
Load: > maximum output signal / 1 mA
24 mm [0.94 in]
20 mm [0.79 in]
12 mm [0.47 in]
10 mm [0.39 in]
6 mm [0.24 in]
3 mm [0.12 in]
PP: -10 ... +80 °C [14 ... 176 °F]
PVDF (option): -10 ... +80 °C [14 ... 176 °F]
Option: -30 ... +120 °C [-22 ... +248 °F]
PP: -10 ... +80 °C [14 ... 176 °F]
PVDF (option): -30 ... +80 °C [-22 ... +176 °F]
PP: -10 ... +80 °C [14 ... 176 °F]
PVDF (option): -30 ... +80 °C [-22 ... +176 °F]
EN
19

Publicidad

loading

Este manual también es adecuado para:

Rlt-2000Rlt-3000