IR measurement
IR temperature
range
-32...380°C
-25,6...716°F
Other technical data
a) response time ...................................................................... less than 1 second
b) spectral response .................................................................................. 8~14μm
c)
emissivity ..................................................... digitally adjustable from 0,10 to 1,0
d) over range indication .................................................. LCD will show "-0L", "0L"
e) polarity
....... automatic (no indication for positive polarity), minus (-) sign for negative polarity
f)
diode laser ......... output <1mW,Wavelength 630~670nm, class 2 laser product
g) operating temp ............................................................... 0 to 50°C (32 to 122°F)
h) storage temp ................................................................ –20 to 60°C (4 to 140°F)
i)
relative humidity
▪ operating ................................................................................... 10%~90%RH,
▪ storage .............................................................................................. <80%RH
j)
memory .................................................................................................... 20 cells
k)
power supply ................. 9V battery, NEDA 1604A or IEC 6LR61, or equivalent
l)
weight ......................................................................................... 290g (10,2 oz.)
m) size ..................................................................................... 190 x 111 x 48mm
n) safety .............................................................................. "CE" Comply with EMC
40
Resolu-
D:S
tion
0,1°C
13:1
0,1°F
DIT-130 – USER MANUAL
Basic accuracy
-32...-20°C
-25,6...-4°F
-20...200°C
-4...392°F
200...380°C
392...716°F
±5°C
±9°F
±(1,5% m.v + 2°C)
±(1,5% m.v + 3,6°F)
±(2,0% m.v + 2°C)
±(2,0%m.v + 3,6°F)