Descargar Imprimir esta página

DITEC EL16 Manual De Instalación página 11

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 30
2.5 Trimmer
R1
Thrust on obstacles (ODS). Adjust the thrust on obstacles before the re-opening
and the stop occurs on the obstacle itself. For very heavy doors and/or doors with
notable friction, a low thrust adjustment may detect an inexistent obstacle.
TC
Automatic closure time. Adjust the time that passes between the end of the
opening manoeuvre and the start of the automatic closing manoeuvre.
RF
Motor output. Adjust the motor output.
VA
Opening speed. Adjust the opening speed.
VC
Closing speed. Adjust the closing speed.
RP
Partial opening. Adjust the range when the command is given between 27-3A (3B).
With the trimmer at minimum, the opening is equal to 5% of the normal opening;
with the trimmer at maximum, the opening is equal to 90% of the normal opening.
2.6 Dip-Switches
Description
DIP1 Direction selection.
The opening direction is intended
by viewing the automation from
the side being examined.
DIP2 Automation type.
DIP3 Safety test contact 41.
DIP1 Batteries.
DIP2 Flat batteries.
DIP3 Block type.
2.7 Signals
LED
POWER ALARM
24 V= power supply.
SA
Safeties 41-6 and 41-8 open.
IN
During the commands: 1-3A, 1-3B and 1-4.
3.
STARTING
ATTENTION: Before performing any type of operation, make sure that the automation is turned off and the batteries are
disconnected.
The operations related to point 3.4 are performed without safeties.
The trimmer can only be adjusted with the automation idle.
3.1
Select the correct direction with DIP1 and the type of automation with DIP2 from the control panel.
3.2
Set trimmers TC, VA, VC to the minimum and trimmers R1, RF, RP halfway.
3.3
Make a jumper on the safeties (41-6 and 41-8) and the stop (1-9).
3.4
Turn on (mains and batteries). SETTINGS RESET with the OPEN button as indicated in paragraph 2.3. Press the ENABLE
button for 3 seconds.
Attention: the control panel performs an automatic POWER RESET on each start and the first opening or closing manoe-
uvre is performed at low speed allowing the automatic self-learning of the stop positions (acquisition).
Check that the automation is operating correctly with further opening and closing commands and set the desired speed with
VA and VC.
3.5
Adjust the thrust on the obstacles with trimmer R1 and the motor force with trimmer RF.
3.6
Remove the jumper and connect the safeties (41-6 and 41-8) and the stop (1-9).
3.7
Select the battery function with DIP1 and DIP2 of the DIR card.
3.8
Adjust the automatic closing with the TC (enabled by command 1-2).
3.9
Set the partial opening with RP if required.
Description
OFF
Right-hand opening for single
door wing automations.
Selection for double door wing
automations.
BIS-TEN-VOLO
Enabled.
Anti-panic operation.
Last operation closing.
Normal block.
ON
11
MIN.
MAX.
0%
100%
0 s
60%
100%
BIS-TEN
0,1 m/s
0,8 m/s
REX
0,1 m/s
0,6 m/s
VOLO
0,1 m/s
0,6 m/s
BIS-TEN
0,1 m/s
0,8 m/s
REX
0,1 m/s
0,6 m/s
VOLO
0,1 m/s
0,6 m/s
5%
ON
Left-hand opening for single door
wing automations.
REX
Disabled.
Continuos operation.
Last operation opening.
Anti-panic block.
Flashing
Encoder / automation fault.
Safety test failure.
Flashes once each time the dip switch and command
1-2 status changes.
Remote
setting
reset
see trimmer
30 s
see trimmer
90%
0,6 m/s
0,6 m/s
0,4 m/s
0,4 m/s
0,4 m/s
0,2 m/s
90%
50%
Remote
setting
reset
see dip-switch
see dip-switch
see dip-switch
ON
OFF
see dip-switch
EL16 - IP1895
GB

Publicidad

loading