Operating Instructions
Safety Switch STP...
30
16
<42>
With plug connector SR11
With plug connector RC18
19
With auxiliary key release
61,5
20
53
4
31
74,7
With escape release (short/long actuator shaft)
Fig. 2: Dimension drawing for STP... without insertion funnel and STP... with insertion funnel
Necessary minimum travel + perm. overtravel
h
Approach direction
Horizontal (h)
Vertical (v)
0,5
For M5 > 35 mm
ISO 1207 (DIN 84)
ISO 4762 (DIN 912)
M = 1.5 Nm
M = 0.8 Nm
red
green
LED module
(optional)
enclosed
separately.
30
Observe assembly
instructions.
<40>
Only for switches with cable entry:
LED module enclosed separately.
Auxiliary release with triangu-
Observe assembly instructions.
Lock function
Type
STP...C1844
Identical locking
Always install the escape
release lever on the
Short actuator shaft
recessed side
Long actuator shaft
Actuator S
Actuator L
standard
insertion funnel
24.5 + 5
28.5 + 5
24.5 + 5
28.5 + 5
Auxiliary release
Locking screw
lar wedge
(2 triangular keys included)
Direction of rotation
Marking
Key removable in
Lock
position
and
Establish a positive
connection between the
shaft and lever.
9
h
30
19
4
9
Actuating head with insertion funnel
33
With wire front release (bowden)
25
With escape release (rotary knob)
Key to symbols
Guard locking ready for operation
/
Guard locking released
/
4
0,5
M = 0.8 Nm
0,5