Usage
Description
This equipment is designed to dispense and
evacuate fluid using compressed air to build
pressure or vacuum in reservoir. Through a
fluid pickup tube connected to a quick-
change coupler, air pressure forces fluid to
dispense out of reservoir or air vacuum pulls
fluid into reservoir. Accessories can be added
to control or direct fluid flow in different
applications.
Operate equipment at input pressure of
90-120 psi (6-8 bar). Regularly check reser-
voir pressure gauge during operation to
ensure pressure remains at or below recom-
mended levels of 25 psi (1.7 bar).
Applications
This equipment is intended to empty or fill
reservoirs with the following fluids: engine
coolant, windshield washer fluid, motor oil,
diesel fuel, automatic transmission fluid
(ATF), brake fluid or power steering fluid.
Accessories can be used to pressure/vac-
uum bleed hydraulic brake or clutch sys-
tems, or refill or top-off sealed automatic
transmissions.
WARNING
Do not use this equipment with gasoline
or other flammable liquids, or with fluids
at temperatures above 175° F (80° C).
Failure to comply could result in death
or serious injury.
DANGER
Do not use this equipment with any fluid
at temperatures above its flash point.
Do not use equipment with any flam-
mable fluid having a flash point below
100 °F (37.7 °C).
Enough vapor to ignite in air may exist
if equipment is used with fluid at a tem-
perature above its flash point, resulting
in fire or explosion.
Failure to comply could result in death
or serious injury.
WARNING
Always wear safety goggles
when operating this equip-
ment. Fluid can splash into
eyes.
Failure to comply could result in death
or serious injury.
Specifications
Inlet pressure
90-120 psi
(6-8 bar)
Operating pressure
20 to 25 psi
(1.4 to 1.7 bar)
Maximum
25 psi (1.7 bar)
reservoir pressure
(170 kPa)
Model
Reservoir
Included accessories
MV7102
2.5 quart (2.5 l) —
MV7105
1.2 gal (5 l)
—
MV7110
2.5 gal (10 l)
Large wand (800816) and small wand (800817)*
MV7120
5 gal (20 l)
Large wand (800816) and small wand (800817)
MV7135
2.5 quart (2.5 l) Brake bleed adapters (822664 and 822694) and refill kit (MVA6832)
MV7412
2.5 gal (10 l)
ATF refill kit (MVA5800A)
MV7840
2.5 quart (2.5 l) Pressure brake bleed adapter kit (MVA6850)
* Indicates change
3
WARNING
Do not exceed 25 psi (1.7 bar) in
reservoir. Relief valve is designed to
prevent this, but if pressure exceeds
25 psi (1.7 bar), immediately discontinue
use and send unit to an authorized
service center for repair or replacement.
Failure to comply could result in death
or serious injury.
Table 1
Fig. 1
Table 2