4.2.2. WORKING MODE *
*
only for wireless master thermostat.
The working mode defines how the system works, It is set on the master thermostat and is
common for all the zones, in other words, every zone will work with the same working mode.
Every zone will work at the same mode.
Selectable working modes are as follows:
• STOP
The air conditioning system will remain not working independently of the demand status of
every zone. Also every motorized outlet will stay shut
• VENTILATION
On this mode the air conditioning unit will be set to on at Ventilation mode any time any zone
is under demand (T
• COOLING
On this mode the air conditioning unit will be set to on at Cooling mode any time any zone is
under demand (T
Cooling modes available on master thermostat will be:
To select among working-modes available do as follows:
Air cooling
Radiant cooling
Combined cooling
On very high humid days, use the dehumectation mode
unit does not dispose of this working mode, follow the manufacturer recommendations,
setting the set point temperatures of zones to the values 25º / 77C to reduce the possibilities
of condensation on the supply grilles
6
When closing motorized outlets, due to security reasons, it will maintain the last one opened for 4 minutes
46
< T
).
Set-Poing
ambient
< T
).
Set-Poing
ambient
*Combined air-radiant cooling.
, short press on the cooling icon.
, press twice on the cooling icon.
, press hold on the cooling icon.
6
.
Air cooling
*Radiant cooling.
. In case your air conditioning