Descargar Imprimir esta página

Allmatic CT INVERTER AM Guia De Instalacion página 16

Publicidad

Idiomas disponibles

Idiomas disponibles

12
13
14
15
16
6-1622596
rev.07
24/11/2022
PHOTOCELLS POWER SUPPLY
Connect the clamp 16 of the control unit to the
clamp + of the power supply of the photocells
receiver.
Connect the clamp 17 of the control unit to the
power supply clamp - of the photocells receiver
and of the transmitter.
Connect the clamp 18 of the control unit to the
power supply clamp of the trasnmitter of the
photocells.
ACCESSORIES OUTPUTS
Accessories output 24Vdc 3W.
MOTOR OUTPUT
Connect the phases of the motor to the clamps
21, 22, 23, an the ground to the clamps 24 or
25.
ATTENTION !! THE MOTOR SHOULD BE
DELTA CONNECTED
For the connection of the motor we recom-
mend to use a screened cables 3 poles +
2
earth 1.5 mm
(type FD781CY)
POWER SUPPLY
Connect the power supply cable to the clamps
26 and 27, connect the ground to one of the
clamps PE 28, 29 or 30.
COURTESY LIGHT
Connect the courtesy light to the clamps 33 and
34, 230Vac 100W MAX.
FLASHING LIGHT
Connect the flashing light to the clamps 31 and
32.
ITA
ENG
FRA
The photocells test test is activated by the MENU A.
ATTENTION: the control unit gives a voltage of 24
Vdc and can supply a maximum power of 3W.
For the safety edges test connect the test device of
the safety edge on the power supply pins of the TX
(test activated wiht low logic signal 0Vdc).
Please refer to the manual of the safety edge.
Before activating the automation make sure that all
the safey devices are correctly cabled and
functioning, refer to the preliminary checkings
section of chap.4
Do not connect the card directly to the electric
network. Put a device which can ensure the
disconnection of each pole from the power supply of
the control unit
Use a cable with correct section according to the
current absorbed by the motor.
It is possible to light up the action area of the
automatism during each motion.
The functioning of the auxiliary light is controlled by
the MENU A.
Use a flashing light without self flashing card
230Vac 60W MAX
ESP
DEU
POR
!! Risk of electric shock !!
4 / 12

Publicidad

loading

Este manual también es adecuado para:

Cst am02