Fireplace and Canopy/Hood Installation
TOP Standoff
Standoff Installation Instructions:
Figure 9 - Mounting Standoff Brackets
1. Position the "Side" Standoff Bracket as shown and start both mounting screws.
Push the Standoff Bracket forward and tighten both mounting screws to position the Firebox for 9/16" Drywall.
Pull the Standoff Bracket backward and tighten both mounting screws to position the Firebox for 1/2" Drywall.
Repeat process for all four "Side" Standoff Brackets.
Standoff Installation Instructions:
2. Attach the "Top" Standoff Brackets by positioning them inline with the mounting holes and inserting the screws.
1 . Position the Standoff Bracket as shown and start both mounting
screws .
Push the Standoff Bracket forward and tighten both mounting
screws to position the Firebox for 1/2" Drywall .
Pull the Standoff Bracket backward and tighten both mounting
screws to position the Firebox for 9/16" Drywall .
Repeat process for all four Standoff Brackets .
2 . Slide the firebox into prepared framing or position firebox in its
final position and frame later .
3 . Level the firebox by checking the top edge of the firebox . Shim if
necessary .
4 . Anchor firebox to the side framing members using 8d nails or
other suitable fasteners . Figure 9 .
5 . The canopy/hood must be installed for safe operation of the
heater .
INSTALLING CANOPY/HOOD
A canopy/hood is furnished with each firebox and MUST be installed
for safe operation . Figure 11
1 . Align the canopy/hood with the holes in the top frame .
2 . Insert all 3 screws slightly but do not tighten .
3 . Push the canopy/hood toward Firebox to insure there is no gap
between the canopy/hood and Firebox as shown in Figure 11a .
4 . Then tighten all screws securely .
WARNING!
Close fireplace screen panel before operating a
decorative type unvented room heater .
WARNING!
The firebox canopy must not be modified or
replaced with a canopy that may be provided
with the unvented decorative room heater .
Slotted Mounting
Hole
#8 x 3/8" Mounting Screws
SIDE Standoff (Nailing Flange)
B
Figure 10 - Nailing Flange Location
Fig. - Nailing Flange Location
Canopy/Hood
Combustion
Casing Top
Figure 11 - Canopy/Hood Installation
FIG. - Hood Installation
NO GAP
(ON BOTH SIDES)
Figure 11a - Canopy/Hood Assembly
10
FIG. 11a
- Hood Assembly
Nailing Flanges
#8 x 3/8 Sheet
Metal Screw