OPERATING PROCEDURE
Note: The burner may be noisy when initially
turned on, To eliminate excessive noise from
the burner, turn the control knob to the LOW
position. Then, turn the knob to the level of
heat desired.
When heater is ON:
Emitter grid will become bright red due to
intense heat. The colour is more visible at
night. Burner will display tongues of blue
flame. These flames should not produce
thick black smoke, indicating an obstruction
of airflow through the burners.
Operation pressure checked:
If the flame is very small, this is because the
supply pressure is not enough. Please refill
gas cylinder.
Re-light:
1. Turn the control knob to OFF position.
2. Wait five (5) minutes before attempting to
relight pilot.
3. Repeat steps beginning with step 2 of the
lighting instruction above.
Shut down instructions:
1. Push in and turn control knob clockwise
to OFF position.
2. Turn LPG cylinder gas valve clockwise to
OFF position when heater is not in use.
Note: After use, some discolouration of the
emitter screen is nomal.
The event of gas leakage:
1. Turn the
control knob
to OFF position.
2. Turn LPG
cylinder valve
to OFF position.
3. Wait 5 minutes to allow gas to dissipate.
4. If odor continues, immediately call
gas supplier.