•
IN: A request to exit button (normally open, momentary
push- button switch) can be connected across "IN" and
"−". When pressed, this button controls the request to exit
function.
•
OUT: Open collector output, 50 mA maximum. It is the first
output of the output control group that is assigned to this
arming station.
Links
See Figure 1.
•
GND (item 2): Must remain fitted.
•
TERM (item 5): Fitted if this device is the last device on
the system databus. For more details see the ATS control
panel installation guide.
Connection from electronics to keypad
See Figure 1, item 1.
Via a standard cable supplied with this product.
Specifications
Supply voltage
Maximum operating current
Dimensions
Operating temperature
Maximum relative humidity
Regulatory information
Manufacturer
PLACED ON THE MARKET BY:
Carrier Fire & Security Americas Corporation Inc.
13995 Pasteur Blvd
Palm Beach Gardens, FL 33418, USA
AUTHORIZED EU REPRESENTATIVE:
Carrier Fire & Security B.V.
Kelvinstraat 7, 6003 DH Weert, Netherlands
Product warnings
THESE PRODUCTS ARE INTENDED FOR SALE
and disclaimers
TO AND INSTALLATION BY QUALIFIED
PROFESSIONALS. CARRIER FIRE &
SECURITY CANNOT PROVIDE ANY
ASSURANCE THAT ANY PERSON OR ENTITY
BUYING ITS PRODUCTS, INCLUDING ANY
"AUTHORIZED DEALER" OR "AUTHORIZED
RESELLER", IS PROPERLY TRAINED OR
EXPERIENCED TO CORRECTLY INSTALL FIRE
AND SECURITY RELATED PRODUCTS.
For more information on warranty disclaimers and
product safety information, please check
https://firesecurityproducts.com/policy/product-
warning/
Certification
Carrier Fire & Security hereby declares that this
device is in compliance with the applicable
requirements and provisions of the Directive
2014/30/EU and/or 2014/35/EU. For more
information see www.firesecurityproducts.com or
www.aritech.com.
2 / 16
10.5 to 13.8 V
70 mA
118 x 75 mm
0 to +50°C
95% noncondensing
or scan the QR code.
REACH
Product may contain substances that are also
Candidate List substances in a concentration
above 0.1% w/w, per the most recently published
Candidate List found at ECHA Web site.
Safe use information can be found at
https://firesecurityproducts.com/en/content/intrusi
on-intro
2012/19/EU (WEEE directive): Products marked
with this symbol cannot be disposed of as
unsorted municipal waste in the European Union.
For proper recycling, return this product to your
local supplier upon the purchase of equivalent
new equipment, or dispose of it at designated
collection points. For more information see:
recyclethis.info
Contact information
www.firesecurityproducts.com or www.aritech.com
For customer support, see www.firesecurityproducts.com
DA: Installationsvejledning
Montering af enheden
Enheden leveres som et kit bestående af et tastatur og seperat
elektronikmodul. RAS Kodetastaturet kan overflademonteres
eller hvis ønsket i et kundespecifikt kabinet.
Bemærk:
Monter enheden i en passende højde, så den er
nem at betjene og LED'erne er synlige.
Tilslutning af centralenhed til ras
kodetastatur
Se figur 3.
I installationsmanualen til ATS-centralen finder du en
vejledning.
Indstillinger for RAS-dipswitch
Se figur 2.
SW1 "Adress" switch1 til 4 (figur 1, punkt 4) bruges til at
indstille RAS-adressen.
LED's
TX (figur 1, punkt 3): LED blinker for at angive, at RAS
kodetastaturet svarer på polling fra ATS-centralen.
LED-indikationer på RAS kodetastaturet
•
ACCESS (Frakoblet): Lyser, når mindst ét af de områder,
der er tildelt RAS kodetastaturet, er frakoblet. Når der
bruges en PIN-kode til at åbne en dør, blinker LED'en,
i den tid døren er låst op.
•
ALM (Alarm): Lyser, når en alarm har været udløst i ét af
de områder, der er tildelt til RAS kodetastaturet.
•
RDY:
- Lyser når området er klar til at blive tilkoblet (system
klar), dvs. at alle zoner er normale, eller
P/N MAINST-ATS1155 (ML) • REV D • ISS 10DEC20