FOR POWER FAILURE COMPENSATION
NOTE
The remote controller is equipped with a power failure compensation function, so it is possible to make the power
failure compensation valid. (At the delivery from the factory, it is set to invalid.)
Consult the dealer you have purchased.
What is the power failure compensation?
G I t means the function that when the power is restored after the power failure or the power switch is intentionally
turned off, the operation is automatically restarted with the setting condition of remote controller before power
failure. When the air-conditioner had been stopping before the power failure, it still keeps on stopping after
power recovery.
G However, resetting by the remote control is necessary for the following items.
1. Timer setting —— It has been cancelled.
2. Auto swing (for the remote control equipped with this function) —— It is stopped at the horizontal position.
REQUEST
When the power failure compensation is set to valid, ensure to turn off the power switch after stopping the operation.
(If the power switch is turned off during the operation mode, the blower of the indoor unit begins to rotate at the
same time when the power switch is turned on. In addition, the outdoor unit begins to operate after about 3 minutes
of the power switch on.)
FOR TEMPERATURE SETTING FIXATION
NOTE
The temperature setting can be fixed by the following operation. After the fixation the temperature change by the
temperature setting switch on the remote controller becomes impossible.
1
REMOTE
COOL
I
FAN
1
SE T TEMP
HI
O
C
O
C
2
FAN
FILTER
TIMER
MODE
RESET
SPEED
TEMP
TIME
AUTO
CHECK
SET
SWING
3
3 2
NOTE
G Release method: Keep on pressing the setting switch for 3 seconds
during operation.
G When the temperature setting switch is pressed while the tempera-
ture setting is fixed, the setting temperature indication flickers for 4
seconds.
When the air-conditioner is stopped:
Press ON/OFF switch to make the air-conditioner in [Opera-
tion] mode.
Press the temperature setting switch.
Press
or
switch to set the unit to the temperature to
be fixed.
Keep on pressing the setting switch for 3 seconds.
By the above operation the temperature setting can be fixed.
WHEN THE CHECK INDICATION LAMP ( RED ) FLICKERS
I The air-conditioner is in abnormal condition.
Air-conditioner No.
Error code
G The air-conditioner stops at the same time when the check display lamp
E
[
~
]
[
~]
begins to flicker.
G The air-conditioner No. is indicated on the time display area and the error
code on the setting temperature display area, all other indication lamps
and the displays go off.
I
I Contact the dealer from which you have purchased to inform [Error
E
code], [Status of failure], [Type of air-conditioner] and [Model name
of unit].
G Press ON/OFF switch to stop the unit.
FAN
FILTER
TIMER
MODE
RESET
SPEED
TEMP
TIME
AUTO
SET
CHECK
SWING
WHEN FILTER SIGN IS INDICATED
When the accumulated operation hour reaches 600 hours, the filter sign is
indicated to inform the cleaning time of air filter. After 8 hours have been
elapsed without any action, the indication changes to flicker.
REMOTE
COOL
I
FAN
SE T TEMP
I When the filter sign is indicated, clean the air filter.
HI
°C
°C
See page 7.
FAN
FILTER
TIMER
MODE
G After the cleaning is finished, press the reset switch of the filter to make
RESET
SPEED
TEMP
TIME
AUTO
the filter sign no-indication. The accumulated operation time is reset.
SET
CHECK
SWING
FOR PREPARATION OF HEATING ( "HOT KEEP" )
"HOT KEEP" is displayed in the following cases.
For the following cases, "HOT KEEP" is displayed on the indication board.
G When heating is started:
In order to prevent blowing out of cool wind, the indoor unit fan is stopped according
to the room temperature which heating operation is started. Wait for approx. 2 to 3
minutes, and the operation will be automatically changed to the ordinary heating
mode.
G Defrosting operation (in the heating mode):
When it is liable to frost, the heating operation is stopped automatically for 5 to 10
minutes once per approx. one hour (Blowing is stopped for both indoor and outdoor
unit.), and defrosting is operated. After defrosting operation is completed, operation
mode is automatically changed to ordinary heating operation.
G When the room thermostat is actuated:
When room temperature increases and room temperature controller actuates, the fan
speed is automatically changed to LO.
When room temperature decreases, air conditioner automatically changes over to
ordinary heating operation.
During "HOT KEEP"
is displayed, a
micro-computer
controls the quantity
of air blow to
prevent blowing out
of cool wind.
9