BYTE N° 10
BIT N° 0x10
BYTE N° 10
BIT N° 0x20
BYTE N° 10
BIT N° 0x40
BYTE N° 11
BIT N° 0x01
BYTE N° 11
BIT N° 0x02
BYTE N° 11
BIT N° 0x80
BYTE N° 26
BIT N° 0x01
BYTE N° 26
BIT N° 0x02
BYTE N° 26
BIT N° 0x08
AIR TEST: command signal for opening the air circuit solenoid-valve. The solenoid-valve stays open
for the entire "command active" time.
0 = no air flow
1 = air flow
WIRE FORWARD: wire extension command signal. The extension speed corresponds to the value set
by the operator. Wire extension stays active for the entire "command active" time.
0 = wire not extended
1 = wire extended
RESET ALARMS: reset alarms command signal.
0 = no reset operation
1 = alarms reset
SAVING WELDING REPORT: control signal for saving welding data into the report (weld@net).
0 = no operation active
1 = save welding data
EMERGENCY: command signal for total shut-down of the welding process. For connection to the
system's safety devices.
0 = system in alarm status
1 = system operating normally
WIRE BRAKE: control signal for the activation of "wire brake" device.
0 = wire brake inactive
1 = wire brake active
PRE-GAS MODE
0=Pre-gas synergic
ARC STRIKING
GAS FLOW-POST GAS
Present
Not present
1=Fixed pre-gas
ARC STRIKING
GAS FLOW-POST GAS
Present
Not present
TIMING COMMUNICATION ALARM
0=0.5 s
1=5.0 s
JOB MODE
0=Standard
Stored job
1=Job freeze
Stored job
PRE-GAS TIMING
NO (reset)
YES
PRE-GAS TIMING
YES
YES
Called job
Job
A+V+...
AI
A+V+...
Called job
Job
A+V+...
Job
A+V+...