Should the machine fail to function correctly, a number of possible causes and the appropriate
solutions are given below:
Problems
The safety valve of the tank will
The compressor
be activated.
does not shut off
No Power
The compressor
will not start
The compressor is difficult to
start
May be caused by a poor seal of
Air loss
a connection.
Probable causes
13
8. TROUBLE SHOOTING
Corrective actions
It is necessary to contact the nearest
authorised Support Service for the repair.
Check Voltage and Ensure switch is
switched on
Check if the motor has overheated for
some reason, causing the temperature
protector to open. Set the switch to «OFF»
state before restarting, and remove the
plug. After the motor cools down, make
sure to connect to the correct power
outlet, and then turn the switch to «ON».
• Whether the voltage of the mains
corresponds to that on the specification
plate
• Whether electrical extension cables are
being used with a faulty core or length.
• Whether the operating environment is
too cold (below 0°C).
• Whether there is electricity supply (plug
properly connected, magneto-thermal
fuses not broken).
• Check all air connections by wetting
them with a soapy water solution (
Never use the solution nearby electric
connections )
• When the tank is empty and being filled.
The user might hear a sisseling sound by
the pressure switch. This is normal and
will stop before the compressor reach a
pressure of 1.5 bar
• Check if the drain valve ( 14 ) is closed
well