9. TROUBLESHOOTING.
Anomaly.
The operation indicator is not
on, the fan does not work,
and there is no welding
current output.
The operation indicator is on,
the fan does not work, and
there is no welding current
output.
The welding process is not
suitable, the welding current
and the arc are not stable.
The fan is running and there
is no welding current. The
yellow LED is on.
The fan works normally, the
indicator is on, but there is no
welding current output.
10. WARRANTY.
Duration of the guarantee period:
• 36 months, according to R.D. 7/2021 of April 27, which modifies the consolidated text of the General Law for the
Defense of Consumers and Users (*) and other complementary laws, approved by R.D. 1/2007, of November 16.
• 12 months, for Companies or Professionals who use the product to carry out an activity for profit.
(*) Royal Decree 1/2007. Article 3. General concept of consumer and user.
For the purposes of this rule..., consumers or users are natural persons who act for a purpose unrelated to their
commercial, business, trade or profession.
Coverage: The guarantee requires the manufacturer CEVIK S.A. to repair or replace for free all components subject
to verified manufacturing defects. The CEVIK Assistance Service will be responsible for the repair or replacement in
the shortest possible time, compatibly with the internal commitments of the service, without any obligation of
compensation or reparation for direct or indirect damages.
Probable cause.
Power failure.
The power supply voltage is not
stable or the input cable is not well
connected.
Polarity of electrode holder and
clamp are not correct. Welding
current too low.
Thermal
protection
activated.
The welding circuit is open due to a
fault in one of the connections.
31
Solution.
Make sure the switch is in the ON
position and the power cord is
plugged into a live outlet.
Turn off the ignition switch and
turn it on again, as the protection
circuit may have been activated. It
may be necessary to leave it for 5-
10 minutes to allow for a reset.
Check that the power cord plug is
firmly connected to a live 230V
power source.
Check the polarity and/or modify the
welding
recommendations
manufacturer of the electrode you
are using.
has
been
Wait for the equipment to cool
down. When the indicator turns off,
you can restart welding.
Turn off the equipment and check
the connections of the electrode
holder
Thoroughly clean the contact area of
the
ground
workpiece.
current.
Follow
the
of
the
and
ground
clamp.
clamp
with
the