Lubrication circuit
GB
Type of lubrication
Circuit fuel supply
Oil change including filter
(standard sump)
Oil quantity at minimum level
(standard sump)
Oil quantity at maximum level
(standard sump)
Oil pressure at minimum speed
(with started engine)
Oil cooling
Cooling circuit
Total capacity of cooling circuit
(excluding radiator and relevant
pipes)
Setting pressure of the expansion
tank plug
Coolant
Coolant maximum temperature
alarm
Exhaust Circuit
DEF fluid
DEF fluid tank capacity
English
Unit of
measure-
ment
The oil quantity at maximum level (12 ÷ 16,5 kg)
depends on the capacity of the oil sump with which
Customer SCHMIDT version 01A: 16,5 KG
liters (kg)
liters (kg)
liters (kg)
bar
liters
bar
50% demineralised or distilled water and 50%
protective radiator fluid with monoethylene glycol
and organic inhibitor formulation complying with
ASTM D 3306 type 1 Standards (Recommended
°C
Aqueous Urea Solution (AUS32) conform to ISO
Do not use solutions with specifications other
During the refilling is essential to avoid con-
tamination of the liquid with other substances
and / or the accidental entry of foreign substan-
ces in the tank
liters
24
R750EU6 - TE4 - IE4 - ISE4
R756EU6
Forced lubrication
Rotor pump
13,8 (12) ÷ 18.9 (16,5)
the engine is equipped.
R756EU6.01A
Oil/water cooler
1.1
fluid PARAFLU UP)
107
22241 specifications
IMPORTANT
i
than those indicated.
14 liters including reserve
2056G