ENGINE OIL DILUTION
Reset the ECU parameters (carry out this
operation after completing the engine oil
GB
change).
In R750EU6 - R750 IE4/TE4/ISE4,
engines after each oil change the "Oil
dilution calculation" function must be
reset. The function is reset by the dia-
gnosis tool available from authorised
workshops or vehicle dealers. If the
diagnosis tool is not available, the fun-
ction can be reset using the following
procedure:
1. Turn the ignition key to ON with the
engine off
2. Press the accelerator pedal fully
down (pedal from 0% to 100%)
3. Wait for 3 seconds before releasing
the pedal.
4. Release the pedal, allow it to return
to the initial position (0%) and wait a
further 3 seconds before pressing it
again.
Repeat the procedure described in
points 2, 3 and 4, 5 times. In some
applications the accelerator pedal pro-
cedure is not feasible: proceed using
the manual accelerator potentiometer.
VERIFICATION:
In some applications the verification is
not feasible.
If the procedure has been done cor-
rectly, the engine oil low pressure light
will flash three times for one second
each, with a pause of 0.5 seconds.
English
R750EU6 - TE4 - IE4 - ISE4
Do not throw the oil in the environment
but carry out its disposal in com-
pliance with legislation in force in the
country where it is used. Use the oils
and lubricators recommended by the
manufacturer. (See "Recommended
lubricants")
64
2056G

Publicidad

loading

Este manual también es adecuado para:

R750te4R750ie4R750ise4