ENGINE OIL DILUTION
Reset the ECU parameters (carry out this
operation after completing the engine oil
GB
change).
In R750EU6 - R750 IE4/TE4/ISE4,
engines after each oil change the "Oil
dilution calculation" function must be
reset. The function is reset by the dia-
gnosis tool available from authorised
workshops or vehicle dealers. If the
diagnosis tool is not available, the fun-
ction can be reset using the following
procedure:
1. Turn the ignition key to ON with the
engine off
2. Press the accelerator pedal fully
down (pedal from 0% to 100%)
3. Wait for 3 seconds before releasing
the pedal.
4. Release the pedal, allow it to return
to the initial position (0%) and wait a
further 3 seconds before pressing it
again.
Repeat the procedure described in
points 2, 3 and 4, 5 times. In some
applications the accelerator pedal pro-
cedure is not feasible: proceed using
the manual accelerator potentiometer.
VERIFICATION:
In some applications the verification is
not feasible.
If the procedure has been done cor-
rectly, the engine oil low pressure light
will flash three times for one second
each, with a pause of 0.5 seconds.
English
R750EU6 - TE4 - IE4 - ISE4
Do not throw the oil in the environment
but carry out its disposal in com-
pliance with legislation in force in the
country where it is used. Use the oils
and lubricators recommended by the
manufacturer. (See "Recommended
lubricants")
64
2056G