Descargar Imprimir esta página

battioni Pagani GARDA EVO Serie Manual De Instrucciones De Uso Y Mantenimiento página 98

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

instruction manual
for use and maintenance of the combined groups for the GARDA EVO series
4.3.3 - CENTRIFUGE PUMP
Hydraulic connection diagram of the operation of the
centrifuge is represented in Figure 1 where the entry of
liquid/slurry "B" and the exit of the liquid/slurry "A" are
highlighted.
WARNING: the centrifuge is not self-priming.
Do not use the centrifuge dry, otherwise the
mechanical seal could burn.
Centrifuge
CENTRIFUGE DODA AFI-27
CENTRIFUGE DODA AFI-27 HS
CENTRIFUGE DODA AFI-35
CENTRIFUGE GARDA 6500
Table 1
4.4 CONTROL DEVICES
To operate the rotary blades vacuum pump turn the lever on the gearbox to the right (position "D").
To operate the centrifuge, turn the handle on the gearbox to the left (position "C").
Selection of the position "C" or "D" of the Garda Evo group must be performed when the PTO is not energised. To
control the suction and compression phases of the rotary blades vacuum pump it is possible to use the handle
located on the manifold, adjustable by hand. To select the phases of suction and compression turn the handle in the
directions indicated in the manual of the individual pumps.
C
page 80
Geometric Flow Rate
m
/h l/min US gpm
3
210 3500
924.6
132 2200
581
270 4500
1188.8
390 6500
1717
D
"B"
Figure 1
Max rev
Max rev
operating
operating
speed
speed
garda evo
centrifuge
cfm
(rpm)
(rpm)
123
1000
2300
77
1000
3350
159
1000
2300
229
1000
2400
The suction-compression selection performed with the handle
of the rotary blades vacuum pump must be carried out with the
pump not activated.
Max absolute
Absorption
pressure
Bar
PSI
kW
hp
6.5
94
70
94
14
202
105
141
11
160
130
174
7
101
60
80.4
Weight
(kg)
153
153
165
132