Using the device
then programs 2-3-4 cannot be selected. The charging pro-
cess continues automatically. Depending on the program
selected, the charging characteristics for voltage, time
and temperature are monitored. With diagnosis program,
revival mode and trickle charging.
Program
1
2
3
4
Program 1
To charge 6 V batteries with a capacity less than 14 Ah.
Press the program selector button
The symbol
charging process, the charging display
shows how far the charging process has progressed
(1 – 4 bars). When the battery is fully charged, the status
display
shows 4 bars. The flashing stops and the device
9
switches to trickle charging automatically.
Program 2
To charge 12 V batteries with a capacity less than 14 Ah.
Press the program selector button
The symbol
charging process, the charging display
shows how far the charging process has progressed
(1 – 4 bars). When the battery is fully charged, the status
display
shows 4 bars. The flashing stops and the device
9
switches to trickle charging automatically.
22
max. (V)
7.3 V
14.4 V
14.4 V
14.7 V
, "6 V", (7.3 V / 0.8 A)
is shown in the LC display. During the
7
, "12 V", (14.4 V / 0.8 A)
is shown in the LC display. During the
4
GB/IE/NI/CY/MT
max. (A)
0.8 A
0.8 A
5.0 A
5.0 A
to select Program 1.
11
flashes and
8
to select Program 2.
11
flashes and
8