Descargar Imprimir esta página

Polaris PB4-60 Manual De Instalación Y Operación página 11

Publicidad

Idiomas disponibles

Idiomas disponibles

Section 5. Maintenance
5.1
Winterizing the Pump
CAUTION
The pump must be protected when freezing
temperatures are expected. Allowing the pump
to freeze will cause severe damage and void the
warranty.
CAUTION
Do not use antifreeze solutions in the pool,
spa, or hot tub systems! Antifreeze is highly toxic
and may damage the circulation system. The only
exception to this is Propylene Glycol. For more
information see your local pool/spa supply store or
contact a qualified swimming pool service company.
1.
Drain all water from the pump, system equipment,
and piping.
2.
Remove the drain plug. Store the drain plug in a
safe location and reinstall it when the cold weather
season is over. Do not lose the o-ring. (Drain Plug
with O-ring Set, R0537000).
Section 6. Product Specifications and Technical Data
6.1
Replacement Parts List
To order or purchase parts for Polaris
what you need, contact Zodiac technical support at 800.822.7933 or www.zodiacpoolsystems.com.
Key
No.
Description
1
Replacement Motor for Booster Pump
2
O-Ring, Backplate, PB4-60
3
Seal, Ceramic and Spring
4
Impeller, PB4-60
5
Volute, PB4-60
6
Bolts with Washers and Nuts
7
Drain Plug with O-Ring, Common
8
Base, Booster, PB4-60
9
Bolts and Washers, Stainless, Motor, PB4-60
10
Quick Connect Install Kit
11
Quick Connect Fittings
12
Pump Hose 6FT Reinforced
13
Backplate PB4-60
|
Polaris
PB4-60 Booster Pump
®
pumps, contact your nearest Zodiac
®
Installation and Operation Manual
3.
Keep the motor covered and dry.
NOTE Covering the pump with plastic will create
condensation, and this moisture will damage
the pump. The best way to protect your pump
is to have a qualified service technician or
electrician properly disconnect the electrical
wiring at the switch or junction box. Once the
power is removed, the two (2) quick connect
fittings can be loosened and the pump stored
indoors. For safety, and to prevent entry of
contaminants, reinstall all conduit and terminal
box covers.
4.
When the system is reopened for operation, make
sure all piping, valves, wiring, and equipment
are in accordance with the manufacturer's
recommendations. Pay close attention to the filter
and electrical connections.
5.
The pump must be primed prior to starting; refer
to Section 4.1, Start-up.
Order Part
Qty
No.
1
P61
1
R0536600
1
R0445500
1
R0536400
1
R0536300
6
R0536900
1
R0537000
1
R0537100
4
R0536800
1
R0617100
4
R0621000
1
P19
1
R0536700
ENGLISH
dealer. If they cannot supply you with
®
Comments
(Includes Drain Plug with O-Ring)
Kit includes 1 ea 6' length of
reinforced hose and 4 ea Quick
Connect fittings.
Comes with 4ea Quick Connect
Fittings and Installation Instructions.
Includes Seal and Backplate O-ring.
Page 11

Publicidad

loading