Before Wiring the Humidifier
CAUTION: Voltage Hazard.
Be sure the humidifier is not plugged in before beginning wiring.
Before wiring the humidifier:
I understand and will comply with applicable local wiring codes and regulations.
What humidifier model do I have?
The model number can be found on the bottom of the humidifier.
NOTE: This file is for the HE400 humidifier.
STEP ONE: Remove the Humidifier Cover
STEP TWO: Install the Transformer
Install transformer on the outside of a grounded metal junction box using only a 7/8 in. (22 mm) knockout
hole. Place mounting tabs into the knockout hole and firmly tighten the locking screw. Field wiring
connections and grounding means for the transformer and enclosure shall be in accordance with the
National Electrical Code (NEC) and the Canadian Electrical Code (CEC). Connect wires to the 120V side of
the transformer.
If included H6062 humidistat is used for humidity control, transformer must provide constant power to the R
and C terminals on the H6062.
STEP THREE: Wiring the Humidifier
Use a wiring diagram from the following pages that matches your equipment.
When wiring is complete, run the wires coming out of the humidifier into the wiring clip on the bottom of the
humidifier.
Humidifier 33-00617EFS—01
Remove the bottom cover.
1
MCR29935
11