Descargar Imprimir esta página

Honeywell Home HE400 Guia De Instalacion página 22

Publicidad

Idiomas disponibles

Idiomas disponibles

Startup and Checkout
When installation is complete, follow the steps below. Make sure the humidifier is running properly before
turning the system over to the homeowner. Once the humidifier is running, day-to-day operation is automatic.
The homeowner can use the control to adjust the humidity levels and turn the humidifier on or off.
3
4
Check all water line and drain connections to ensure there are no leaks before leaving the job site.
• Check for leaks immediately after turning the main water supply on, and again after 15 minutes of
humidifier operation.
Turn the setpoint to the homeowner's desired level when testing is complete. If humidity is not needed, set
the control to Off, and turn the Damper Position knob on the bypass outlet so that it is perpendicular to the
bypass outlet.
20
1
5
MCR34841
Snap the bottom cover into place.
Turn on the water supply at the saddle valve or
T-fitting and manual shutoff valve. Water will flow to
the humidifier but will not pass through the pad until
the humidity control is turned on.
Turn on power to the transformer that powers the
2
humidifier.
Turn the Damper Position knob on the bypass outlet
so that it is parallel to the bypass outlet.
Turn the humidity control to On.
• If your wiring is configured for operation only
with heat or fan, make the appropriate system
demands to allow humidification.
• Make sure air is blowing through the ductwork
with the humidifier call.
Remove the humidifier's top cover to verify water
flow through the top tray and into the pad.
Humidifier 33-00617EFS—01

Publicidad