Table 1 Indigo300 operating environment
Property
Operating temperature
Storage temperature
Operating humidity
Maximum operating altitude
IP rating
Note: Protect the device from direct sunlight.
Table 2 Indigo300 inputs and outputs
Property
Power supply input
Fuse size for power supply
Transmitter service port connection
Analog outputs
Number of analog outputs
Selectable voltage output types
Selectable current output types
Accuracy of analog outputs at 20 °C (+68 °F)
Temperature dependence
Current consumption at 20 °C (+68 °F) (U
Do not modify the unit or use it in ways not described in the
If the equipment is used in a manner not specified by Vaisala, the
24 V DC)
in
Description/Value
−20 ... +60 °C (−4 ...+140 °F)
−30 ... +70 °C (−22 ...+158 °F)
0 ... 100 %RH
5000 m (approx. 16 400 ft)
IP65: Dust-tight. Protected from powerful water
jets from any direction.
Description/Value
1)
15 ... 30 V DC
24 V AC ±10 % 50/60 Hz
2.5 A
• Connection to Insight with USB2 and cable
2)
262195
• Connection to Indigo80 with cable 262195
Current or voltage
3
0 ... 1 V, 0 ... 5 V, 0 ... 10 V, 1 ... 5 V, scalable,
R
≥ 10 kΩ
L
4 ... 20 mA, 0 ... 20 mA, scalable, R
3)
±0.1 % full scale
±0.005 % / °C full scale
≤ 500 Ω
L
7