Descargar Imprimir esta página

poolstar SPAWER POOLEX O'SPA Manual De Instalación página 123

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 35
4.12
Advanced settings
WARNING: This operation is used to assist servicing and future repairs.
The default settings should only be modified by an experienced professional person.
The system's settings can be checked and adjusted via the remote control by following
these steps
Caution, some settings cannot be modified, check the settings table for more information.
Step 1: Switch off the heat pump.
Step 2: Keep pressing
Step 3: Select the desired setting using the down and up arrows
Step 4: Press on
to select the setting to be adjusted.
Step 5: Press on
to save the new value.
Parameters
Indication
C0
Setting inlet water temp in heating mode
C1
Water temp difference for restart in heating mode
C2
Auto restart(0-without, 1-with)
C3
Protection setting for too high discharge temp
C4
Max. inlet water setting temp in heating mode
C5
Min. inlet water setting temp in heating mode
C6
Difference water temp to stop in heating mode
C7
Setting inlet water temp in cooling mode
C8
Water temp difference for restart in heating mode
C9
Difference water temp to stop in cooling mode
C10
Max. inlet water setting temp in cooling mode
C11
Min. inlet water setting temp in cooling mode
C12
Protection setting for too low ambient temp
C13
Protection setting for too high ambient temp
C14
Protection temp difference for ambient temp
C26
AUX turn On ambient temp in heater Auto mode
C27
AUX water temp difference for restart in heater Auto mode
C28
AUX water temp difference for restart in Manual mode
C29
Setting inlet water temp in Auto mode
C30
PUMP parameter
C31
PUMP working interval of time
C32
AUX parameter
H0
Defrosting mode activation timer
H1
Defrosting mode max. duration
H2
Defrosting exit coil temp
H3
Defrosting entry coil temp
H4
Temp difference between defrosting entry ambient temp
and coil temp
H5
Min. Ambient temp to entry defrosting
P1
CN6 function selection
When OFF, pressing on
4. Use
for 3 seconds to access the settings.
for 5 seconds resets the settings to factory settings.
Default
Adjustment range
V.
15°C~40°C
38°C
1°C~10°C
3°C
0~1
1
30°C~120°C
110°C
30°C~60°C
40°C
5°C~30°C
15°C
0°C~18°C
0
7°C~30°C
26°C
0°C~18°C
3°C
0°C~18°C
0
20°C~35°C
30°C
2°C~18°C
7°C
-25-20°C
-7°C*
35-60°C
42°C
1-10°C
1°C
0°C ~ 20°C
15
1~5°C
5
1~5°C
2
7°C~40°C
38°C
0 (deactivated)
0
/1 (activated)
30-90 min
60 min
0 (deactivated)
1
/1 (activated)
1~240min
45 min
1~25min
8 min
1~25°C
12°C
-20~20°C
-1°C
0~15°C
5°C
0~20°C
20°C
0 : no function
3
1 : high pressure
switch (reserved)
2 : water flow switch
(reserved)
3 : in.grip function
Comments
adjustable
adjustable
adjustable
adjustable
adjustable
adjustable
adjustable
adjustable
adjustable
adjustable
adjustable
adjustable
adjustable
adjustable
adjustable
adjustable
adjustable
adjustable
adjustable
adjustable
adjustable
adjustable
adjustable
adjustable
adjustable
adjustable
adjustable
adjustable
EN
| 25

Publicidad

loading