Installation
Note: Not for use in vans or trailers, food
trucks or similar vehicles.
Note: If the unit has not been stored or
moved in an upright position, let it stand
upright for approximately 12 hours before
operation. If in doubt allow to stand.
1. Remove the appliance from the packaging.
Make sure that all protective plastic film and
coatings are thoroughly removed from all
surfaces.
2. To optimize performance and longevity, ensure
a minimum clearance of 2.5cm is maintained
between the unit and walls and other objects,
with a minimum 20cm clearance on the top.
NEVER LOCATE NEXT TO A HEAT SOURCE.
Note: Before using the appliance for the
first time, clean the interior with soapy
water then dry well.
Operation
Storing Food
To get the best results from your POLAR appliance,
follow these instructions:
It is important that food entering the Blast
Chiller/Freezer does not exceed a temperature
of 90°C.
It is recommended that metal containers /
trays are used as other materials such as
plastic or polystyrene containers will act as an
insulator and extend blast chilling times.
Sufficient space must be left between products
in order to guarantee a sufficient flow of cold
air. Ensure product is not in contact with the
internal walls of the unit, and leave sufficient
gaps between trays.
Never obstruct the inlet of the evaporator fans.
Products that are more difficult to chill because
of their composition and size should be placed
in the centre of the unit.
16
CK640_ML_A5_v5_20221025.indb 16
CK640_ML_A5_v5_20221025.indb 16
Blast chilling data refers to standard products
(low fat content) with a thickness below
50 mm: therefore avoid overlaying products
on trays or the insertion of pieces with a
much higher thickness, as this will lead to
an extension of blast chilling times. Always
distribute the product well on the trays and in
the case of thick pieces decrease the amount
to blast chill.
Limit the number of times and the duration of
time the doors are opened.
The chiller should be used for storage for short
periods only.
When removing product that has undergone
blast chilling/shock freezing, always wear
gloves to protect the hands from cold burns.
Introduction
The appliance has the following operational states:
On
The appliance is switched on and
an operating cycle is running
Standby
The appliance is switched on but
no operating cycle is running
Off
The appliance is not switched on
If power is interrupted during a timed blast
chilling operation, when power is restored,
chilling will continue from the time point
at which the interruption occurred (with a
maximum error of 10 minutes).
If power is interrupted during a set-
temperature blast chilling operation, when
power is restored, chilling will start again from
the beginning.
If power is interrupted during a storage
operation, when power is restored the storage
operation will be reset.
If power is interrupted while in "stand-by"
mode, when power is restored the device will
be in the same state.
Turn On
1. Ensure the power switch is set to [O] and turn
on at the socket.
2. Switch on the Power [I]. This will place the
unit in standby whilst waiting for the cycle to
be selected.
2022/10/25 17:35
2022/10/25 17:35