EN
DATA HEAD
To adjust the HPF to minimum
To adjust the HPF to maximum
NOTE 1-
The "channel number" byte indicates the channel operated, in that case, 00 is channel 1, 01 channel 2, 02 channel 3, 03 xhannel 4, 04, channel 5, 05, channel 6, 06 channel 7, 07 channel 8.
Number upon this value, always operates over the MASTER
NOTA 2-
El byte de "Parameter Range" indicate theHPF adjustment value from 20 Hz (min) to 130 Hz (max.)
DATA HEAD
To adjust the LPF to minimum
To adjust the LPF to maximum
NOTE 1-
The "channel number" byte indicates the channel operated, in that case, 00 is channel 1, 01 channel 2, 02 channel 3, 03 xhannel 4, 04, channel 5, 05, channel 6, 06 channel 7, 07 channel 8.
Number upon this value, always operates over the MASTER
NOTA 2-
El byte de "Parameter Range" indicate the HPF adjustment value from 6000 Hz (min) to 16000 Hz (max.)
DATA HEAD
To adjust the Feedback to minimum
To adjust the Fdeedback to maximum
NOTE 1-
The "channel number" byte indicates the channel operated, in that case, 00 is channel 1, 01 channel 2, 02 channel 3, 03 xhannel 4, 04, channel 5, 05, channel 6, 06 channel 7, 07 channel 8.
Number upon this value, always operates over the MASTER
NOTA 2-
El byte de "Parameter Range" indicate the Feedback adjustment value from OFF (min) to 04 (max.)
PARITY bit
Channel Number
FE
0D
00
from CH1 to 8 physic
FE
0D
00
PARITY bit
Channel Number
FE
0D
00
from CH1 to 8 physic
FE
0D
00
PARITY bit
Channel Number
FE
0D
00
From CH1 to 8 physic
FE
0D
00
9
HPF ADJUSTMENT
ID Number
Empty
Parameter Range
06
00
00
HPF
20 Hz
06
00
3f (130 in decimal )
130 Hz
LPF ADJUSTMENT
ID Number
Empty
Parameter Range
07
00
00
LPF
6000Hz
07
00
64(100 in decimal )
16000Hz
Feedback ADJUSTMENT
ID Number
Empty
Parameter Range
08
00
00
FeedBack
OFF
00
00
04
User Manual / Manual de uso
Empty
Empty
Empty
00
00
00
00
00
00
Empty
Empty
Empty
00
00
00
00
00
00
Empty
Empty
Empty
00
00
00
00
00
00
MD 82 AX
Data Tail
FF
FF
Data Tail
FF
FF
Data Tail
FF
FF