Having trouble?
Draining water or motor rotation sound is heard.
Nothing appears in the wireless remote controller display, the display
is faint, or signals are not received by the indoor unit unless the remote
controller is close.
The operation lamp near the receiver for the wireless remote controller on
the indoor unit is blinking.
Model
Power source(voltage <V>/Frequency<Hz>)
Rated Input(Indoor only)
Rated Current(Indoor only)
Heater
Dimension(Height)
Dimension(Width)
Dimension(Depth)
Noise level(Low -Middle-High)
Net weight
Model
Power source(voltage <V>/Frequency<Hz>)
Rated Input(Indoor only)
Rated Current(Indoor only)
Heater
Dimension(Height)
Dimension(Width)
Dimension(Depth)
Noise level(Low -Middle2-Middle1-High)
Net weight
Model
Power source(voltage <V>/Frequency<Hz>)
Rated Input(Indoor only)
Rated Current(Indoor only)
Heater
Dimension(Height)
Dimension(Width)
Dimension(Depth)
Noise level(Low -High)
Net weight
20
<Cooling/Heating>
PKA-RP35HAL PKA-RP50HAL
~/N 230/50
<kW>
0.04/0.03
0.04/0.03
<A>
0.40/0.30
0.40/0.30
-
<kW>
295
<mm>
898
<mm>
249
<mm>
9-10.5-12
<m
3
/min>
36-40-43
<dB>
13
<kg>
PCA-RP50KAQ
PCA-RP60KAQ
0.05/0.05
0.06/0.06
<kW>
0.37/0.37
0.39/0.39
<A>
<kW>
-
<mm>
<mm>
960
<mm>
10-11-13-15
15-16-17-19
<m
3
/min>
32-34-37-40
33-35-37-40
<dB>
25
<kg>
PCA-RP71HAQ PCA-RP125HAQ
~/N 230/50
0.09/0.09
0.26/0.26
<kW>
0.43/0.43
1.19/1.19
<A>
-
<kW>
<mm>
280
<mm>
1136
1520
<mm>
650
3
/min>
17-19
30-38
<dB>
34-38
44-50
<kg>
41
Here is the solution. (Unit is operating normally.)
When cooling operation stops, the drain pump operates and then stops.
Wait approximately 3 minutes.
The indoor operation sound level is affected by the acoustics of the
particular room as shown in the following table and will be higher than
High sound
absorbing rooms
Broadcasting
Location
studio, music
examples
room, etc.
Noise levels
The batteries are low.
Replace the batteries and press the Reset button.
If nothing appears even after the batteries are replaced, make sure that
the batteries are installed in the correct directions (+, –).
The self diagnosis function has operated to protect the air conditioner.
Do not attempt to repair this equipment by yourself.
Turn off the power switch immediately and consult your dealer. Be sure
to provide the dealer with the model name.
-
PCA-RP71KAQ PCA-RP100KAQ PCA-RP125KAQ PCA-RP140KAQ
~/N 230/50
0.06/0.06
0.09/0.09
0.42/0.42
0.65/0.65
-
-
-
230
1280
680
16-17-18-20
22-24-26-28
35-37-39-41
37-39-41-43
32
36
-
56
Low sound
Normal rooms
absorbing rooms
Reception room,
hotel lobby, etc.
3 to 7 dB
6 to 10 dB
0.11/0.11
0.14/0.14
0.76/0.76
0.90/0.90
-
-
1600
23-25-27-29
24-26-29-32
39-41-43-45
41-43-45-48
38
39
room
9 to 13 dB