C1 Automatic closing from partial opening
secs and mins
000= OFF
001.010 keep-open time secs.*
(001 = 5secs... 010 = 50secs)
011..040 keep-open time min*
(011=1min... 040=30min) * plus warning time
C2 Partial opening in 5cm steps 000..100
C3 Lighting time, after motor running
000..060 (10sec. steps)
C4 Close after leaving the photo cell, 000..0.019, 0.5
s
C5 EMERGENCY stop input
000= automatic closing after EMERGENCY STOP
locked
001= closing time starts again after release
EMERGENCY stop
C6 Function connections
Connection 3
000
STOP
STOP
001
STOP
STOP
002
STOP
STOP
003
OPEN
CLOSE
C7 PARKING ASSISTANT operator light flashes
when door can be closed
000= OFF 001= ON
(only in connection with photo cell)
1) If the added load (A5, A6) is >003 and/or the
automatic closing (b4, c1) is set to ON (>000), the door
may only be operated with an additional safety device.
WARNING: to ensure that the closing force value comply with
limits established by the EN 12453 standard für door models
Basematic 42, Superior 42/+42/+42 WIDE with pass door,
Secura with pass door, Comfort with pass door and SSD, the
following parameters values must be set: A1 = 008; A2 = 003
and A6 = 000. This operation must be performed only by
qualified personnel.
19 Reset
ATTENTION: There is no longer any protection by
switching off the load after the reset. Teach the door
operator in again before re-commissioning. For this carry out
Teaching in the door operator (Chapter 15) .
Reset (saved values of the teach-in runs)
Press and hold buttons
and menu
during one of the 3 status messages A, B or C (see
Chapter 10). The indicator lamp (rES) flashes after a few
seconds then L4 is displayed and the reset is made.
The remote transmitters are not deleted.
Reset, factory setting
• Pull out plug (1, green).
Magic 1000-3
1)
000
020
012
000
000
000
Connection 4
Partial opening
STOP
STOP
STOP
STOP
000
simultaneously
IP2286 11/2021
• During one of the 3 status messages A, B or C (see 10)
press the pushbuttons
and Menu
longer than 12 seconds. The display flashes slowly at first,
then quicker (rES). Then the status display reappears, the
reset is made.
The values shown under Programming (Chapter 18) are
set. The remote transmitters are not reset.
20 Attaching additional safety devices
Photo cell
Function: When the safety input is activated (opening the
contact) the operator stops and reverses as far as the OPEN
end position.
If the "automatic closure" function is also activated, following
the third successive obstruction message, the operator will
move to the OPEN end position and shut down.
Connection: Pull out plug with yellow bridge on the external
junction 2 and store it. Plug on safety device.
Safety edge, opto-sensor and warning light are connected by
extension modules.
EMERGENCY stop
Function: If the external safety device is operated when the
door is moving (Contact opened), the door stops immediately.
Once the EMERGENCY stop contact has closed, the door
operator can be moved again with the next pulse.
Connection: Pull out plug with green bridge on the external
junction 5 and store it. Plug on safety device.
21 Additional connections
Additional lighting
Connection must be performed only by qualified electricians.
In addition to the operator light (5 W LED lamp), optional
lighting of a maximum of 60 W (no tubular fluorescent lamps)
can be connected to terminals 1 and 2.
Note: Some energy-saving lamps can interfere with the radio
signal.
External pulse input
An external pulse signal (e.g. wall button) can be connected
to terminals 14 and 15. Fixed control devices like buttons or
similar should be installed at a height of at least 1,5 m and
within sight of the door but away from moving parts. Key
actuated switches can be installed at lower height.
simultaneously for